Rewrite setting value, 2 i/o communication, Co mm u ni c a ting w ith t he g t 2 s er ie s – KEYENCE DL-DN1 User Manual

Page 44

Advertising
background image

3-2 I/O Communication

3-14

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -

3

Co
mm

u

ni

c

a

ting
w

ith t
he G

T

2

s

er

ie

s

Rewrite setting value

Sensor amplifier ID numbers 01 to 15 are assigned to bits 0 to 14, respectively.

For details of communication methods, see

"Rewriting a Setting Value of a Sensor

Amplifier" (page 3-20).

3-output mode

OUT area

m: The first device number assigned to the DL-DN1

IN area

n: The first device number assigned to the DL-DN1
The device assignments are the same for all 3-output modes including extended
modes.

Device

(DEC)

Name

Bit 7

Bit 6

...

Bit 1

Bit 0

Bit 15

Bit 14

...

Bit 9

Bit 8

m+3

Request to rewrite HIGH

setting

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

m+4 to 5

HIGH setting

High setting to be rewritten (4-byte signed integer)

m+6

Request to rewrite LOW

setting

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

m+7 to 8

LOW setting

Low setting to be rewritten (4-byte signed integer)

m+9

Request to rewrite PRESET

setting

ID08

ID07

...

ID02

ID01

Reserved

ID15

...

ID10

ID09

m+10 to 11

PRESET setting

PRESET setting to be rewritten (4-byte signed integer)

Device

(DEC)

Name

Bit 7

Bit 6

···

Bit 1

Bit 0

Bit 15

Bit 14

···

Bit 9

Bit 8

n+7

Setting-value rewrite error

ID08

ID07

···

ID02

ID01

Reserved

ID15

···

ID10

ID09

n+8

HIGH setting rewrite

complete

ID08

ID07

···

ID02

ID01

Reserved

ID15

···

ID10

ID09

n+9

LOW setting rewrite

complete

ID08

ID07

···

ID02

ID01

Reserved

ID15

···

ID10

ID09

n+10

PRESET setting rewrite

complete

ID08

ID07

···

ID02

ID01

Reserved

ID15

···

ID10

ID09

Advertising