Checking the package contents, Package contents, Names of each part – KEYENCE DL-PD1 User Manual

Page 2: Installation and connection to sensor amplifiers, Mounting on a din rail, How to connect to the sensor amplifier

Advertising
background image

2

E DL-PD1_IM

Before using the DL-PD1, make sure that the following equipment and accessories are

included in the package.

We have thoroughly inspected the package contents before shipment. However, in the event

of defective or broken items, contact your nearest KEYENCE office.

Package Contents

Mounting on a DIN rail

1

Fit the tab of the lower part of the main

unit to the DIN rail. While inserting the

main unit in the direction of arrow 1,

push the body in the direction of arrow 2.

2

To detach the main unit, while

pushing the main unit in the

direction of arrow 1, pull the body in

the direction of arrow 3.

How to connect to the sensor amplifier

The DL-PD1 is used by connecting it to a sensor amplifier. The connection method

varies according to the mounting type of the sensor amplifier to connect to.

Connecting to a DIN rail mounting type sensor amplifier

1

Detach the expansion protective cover of the sensor amplifier to

which the communication unit is to be connected.

2

Mount the DL-PD1 on the DIN rail and connect to the sensor

amplifier.

Push and fix the DL-PD1 to make sure there is no space between the output unit and the

sensor amplifier.

3

Mount the attached end units (OP-26751: a set of two pieces) on

both sides of the sensor amplifier and the DL-PD1, then fix the end

units with screws on the upper part of each end unit (2 points x 2

units).

The mounting method of the end unit is the same as that of the DL-PD1.

Checking the Package Contents

• DL-PD1 main unit x 1

• End units (OP-26751: a two-unit set) x 1

• Expansion connector sticker x 1

• Ferrite core x 1
• Instruction manual x 1

Names of Each Part

Item

Description

(1) Station Failure Indicator

Normal lighting is as below.

: OFF

: OFF

: Lit in green

: Lit in green

Refer to the User’s Manual for the DL-PD1 for details.

(2) Bus Failure Indicator

(3) Data Exchange Indicator

(4) Sensor communication

indicator

(5) Station address setting

switch

Set the station address.

The place of x10: 10, the place of x1: 1

[Setting range]: 01 to 99, [Default value]: 11

(6) PROFIBUS connector

D-sub9 pin (socket) connector compliant with the RS-485.

(7) Sensor amplifier

connector

Attach the sensor amplifier to this connector.

When shipped from the factory, a protection cover is

installed.

(1) Station Failure Indicator

(2) Bus Failure Indicator

(3) Data Exchange Indicator

(4) Sensor amplifier communication

indicator

(5) Station address setting switch

(6) PROFIBUS DP connector

(7) Sensor amplifier connector

The station address of the DL-PD1

cannot be set to 00, 100, or more.

Important

Installation and Connection to Sensor Amplifiers

When connecting the DL-PD1, be sure to check the power of

sensor amplifier is OFF before performing the operation.

Performing the operation when the power of sensor amplifier is

ON may damage the equipment.

Refer to the Instruction Manual of each sensor amplifier for

details about how to add the sensor amplifier.

Refer to the figure below, and check that the sensor

amplifier connector (for DIN rail mounting type) on the side

of the DL-PD1 is not mounted at an angle. Connecting to the

sensor amplifier with the connector diagonally may damage

the equipment.

Be sure to insert the DL-PD1 to the sensor amplifier to the

end. Turning on the power with diagonal insertion or

improper insertion may damage the equipment.

(1)

(2)

(3)

NOTICE

Point

Sensor amplifier

Expansion protective cover

Sensor amplifier

DL-PD1

Connector

NOTICE

Sensor amplifier connector

DL-PD1

End unit

End unit

NOTICE

Advertising