Make other settings as necessary, Il-e, Basic oper ations – KEYENCE IL Series User Manual

Page 34: Analog output scaling" (page 4-27), Power on

Advertising
background image

3-2

IL-E

3

Basic Oper

ations

3-1

Operation When the Power is Turned on for the First Time

When the amplifier is turned on for the first time after the sensor head is connected, the
initial setting screen appears after a few seconds. Make the initial settings according to the
following procedure.
The initial setting is necessary for both the main unit and the expansion units when units
are added.

4

Make other settings as necessary.

Point

Once the initial setting is completed, the initial setting display will
not appear when the power is turned on the second time or the after.
To change these settings, perform an initial reset.

"3-3 Initial Reset (Initialize)" (page 3-8)

1

Press S/T button to select the polarity of judgment
output and edge check output, and then press [MODE]
button.

[MODE] button

2

Press S/T button to select the type of analog output
and press [MODE] button. (for IL-1000 / IL-1500 only)

"10. Analog Output Scaling" (page 4-27)

[MODE] button

3

After the setting is complete, [end] blinks several
times on the sub display and the main screen
appears.

Power ON

PRP

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

QWV

GO

HOLD

CALC

CHECK

Output polarity

Setting value

Description

npn

NPN output

pnp

PNP output

QHH

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

#P.)

GO

HOLD

CALC

CHECK

Analog output

Setting value

Description

off

Not output

0-5 u

Analog output after the judgment value (P.V.) is converted to

the range from 0 to 5 V.

-5-5 u

Analog output after the judgment value (P.V.) is converted to

the range from -5 to 5 V.

1-5 u

Analog output after the judgment value (P.V.) is converted to

the range from 1 to 5 V.

ampr

Analog output after the judgment value (P.V.) is converted to

the range from 4 to 20 mA.

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

GO

HOLD

CALC

CHECK

'PF