USING EACH FUNCTION SAMPLING CYCLE SELECTION

OFF

ON

0

MON(V)

MON(mA)

1

2

3

AUTO

GAIN

LOW

HIGH

TIMING

STABILITY

ZERO/RESET

24V DC IN

REMOTE

GND

TIMING

ZERO

GND

ALARM

GND

NEAR

FAR

RESET

BRIGHT

DARK

LASER ON

SHIFT

SPAN

+

2

3

1

• When measuring a target that reflects a small amount of light,

such as black rubber:
Set a longer sampling cycle.

Note: When a short sampling cycle is set for measuring a target that has
low reflectance, detection may become unstable or an alarm output is
produced due to the extremely small amount of light being received.

• When measuring a target that reflects a large amount of light

such as a mirror-surfaced or metallic object:
Detection is available with a short sampling cycle setting.
Make sure it operates with the actual target.
There are four available settings for the sampling cycle: 128, 256, 512,
and 2048

µs. The initial setting is 2048 µs.

Setting the sampling cycle

1. Turn off the key-operated laser switch.

2. Hold down both the

and

keys for the SHIFT adjustment, and

then press the

key for the SPAN adjustment.

The sampling cycle setting changes in sequence.

Checking the sampling cycle setting

The LED corresponding to the current sampling cycle setting illuminates.

TIMING STABILITY

BRIGHT

2048

µs

512

µs

256

µs

128

µs

DARK

LASER ON

One of these LEDs illuminates.

The LED corresponding to the current
sampling cycle setting illuminates.