The data to the measuring instrument is assigned to the OUT area of the EtherNet/IP
scanner.

„

Control Data (62 Words (124 Bytes)) assembly instance (Instance ID): 65H

For details on each parameter, refer to "Parameter List" (Page 3-22).

Assignment to OUT Area (Scanner to CB-EP100)

CB-EP100 data

Scanner's OUT area

Address 0
Address 1

Address 123

External Input
(Assembly Instance: 101)

1-byte (8-bit) data

Name

Address

(Byte)

bit7

bit6

bit5

bit4

bit3

bit2

bit1

bit0

Error clear

request

0

Reserved for system

Error clear

request

1

Reserved for system

Reserved

for system

2

-

11

Reserved for system

Timing

request

12

Timing

request

OUT8

Timing

request

OUT7

Timing

request

OUT6

Timing

request

OUT5

Timing

request

OUT4

Timing

request

OUT3

Timing

request

OUT2

Timing

request

OUT1

13

Timing

request

OUT16

Timing

request

OUT15

Timing

request

OUT14

Timing

request

OUT13

Timing

request

OUT12

Timing

request

OUT11

Timing

request

OUT10

Timing

request

OUT9

Auto-zero

request

14

Auto-zero

request

OUT8

Auto-zero

request

OUT7

Auto-zero

request

OUT6

Auto-zero

request

OUT5

Auto-zero

request

OUT4

Auto-zero

request

OUT3

Auto-zero

request

OUT2

Auto-zero

request

OUT1

15

Auto-zero

request

OUT16

Auto-zero

request

OUT15

Auto-zero

request

OUT14

Auto-zero

request

OUT13

Auto-zero

request

OUT12

Auto-zero

request

OUT11

Auto-zero

request

OUT10

Auto-zero

request

OUT9

Reset

request

16

Reset

request

OUT8

Reset

request

OUT7

Reset

request

OUT6

Reset

request

OUT5

Reset

request

OUT4

Reset

request

OUT3

Reset

request

OUT2

Reset

request

OUT1

17

Reset

request

OUT16

Reset

request

OUT15

Reset

request

OUT14

Reset

request

OUT13

Reset

request

OUT12

Reset

request

OUT11

Reset

request

OUT10

Reset

request

OUT9

External

input

request

18

Reserved for system

Storage

stop request

Storage

start request

Batch

end

request

Batch

start

request

Trigger

request

19

Reserved for system

Memory

clear

request

Reserved

for system

Reserved

for system

20

-

27

Reserved for system

Advertising