KEYENCE LS-9030D User Manual

Instruction manual

Advertising
background image

E LS-9006D/LS-9030D

1

LS-9006D/LS-9030D

Instruction Manual

Read this manual before using the product in order to achieve maximum

performance.

Keep this manual in a safe place after reading it so that it can be used at

any time.

Introduction

This Instruction Manual provides the hardware information of the LS-9006D/

LS-9030D.

When reading the information pertaining to the usage methods and the

“WARRANTIES AND DISCLAIMERS” section, be sure to also read the

corresponding parts of the “LS-9000 Series User's Manual.”

Keep this manual in a safe place for future reference.

Ensure that the end user of this product receives this manual.

Safety precautions on laser products

z

Symbols

The following symbols alert you to important messages. Be sure to read
these messages carefully.

Mounting the Head

Mounting method

z

Using the top mounting holes

Secure the head by inserting the provided hexagon socket bolts (M6 x
L25) through the mounting holes on the base surface and tightening them.
Maximum tightening torque value

• LS-9006D 5.2 N m
• LS-9030D 5.2 N m

LS-9030D mounting example

z

Using the bottom mounting holes

Secure the head using the mounting holes located on the bottom panel of
the base (M6 12 mm deep).
Maximum tightening torque value

• LS-9006D 5.2 N m

• LS-9030D 5.2 N m

LS-9030D mounting example

Using the Air Purge Unit

At the time of shipping, the air purge unit is attached to the sensor head. By

using the air purge unit, you can reduce the dirt on the transmitter and

receiver caused by water, dust and other debris.

How to use the air purge unit

z

LS-9006D

To use LS-9006D’s air purge unit, prepare the following off-the-shelf items:

• PC6-M5 (PISCO fitting) (Recommended)
• Air tube (Outer diameter

φ

6

1

Attach the fitting on the air purge unit.

Recommended tightening torque: 1 to 1.5 N m

2

Insert the air tube into the fitting.

When cleaning the receiver, remove the air purge unit that is secured
with four screws as shown below.
Maximum tightening torque for securing the unit: 1.5 N m

It indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in
product damage as well as property damage.

It indicates cautions and limitations that must be followed
during operation.

It indicates additional information on proper operation.

96M12695

DANGER

WARNING

CAUTION

NOTICE

Important

Point

If you use an L-shaped fitting, make sure that the threaded
portion will not become loose due to twisting of the tube.

• Supply air flow rate:

20L/min to 40L/min

• Air pressure:

Approx. 60 kPa

The air pressure is measured before the air purge. The
pressure will vary depending on the point of measurement.
Be sure to check the performance based on the air flow.

• Be sure to use clean, dry air.
• The air purge performance and the measurement accuracy of

the sizer can be affected by the usage environment and/or the
condition of the air source. Determine the specifications for
the air source and the glass cleaning schedule in accordance
with the actual operating conditions.

NOTICE

Important

Advertising