Chapter 6 Normal Mode

43

6

OFF

–A1/4

+A1

+A1/2

+A1/3

+A1/4

–A1

–A1/2

–A1/3

3. Set the calculation modes.

Every time you press the [CALCULATE] button, the setting changes as shown
below. (For AREA 1)

OFF:

Calculation is set to OFF.

+A1:

The measured value is output without changes.

+A1/2: The measured value is multiplied by “1/2”.

+A1/3: The measured value is multiplied by “1/3”.

+A1/4: The measured value is multiplied by “1/4”.

–A1:

The measured value is multiplied by “–1”.

–A1/2: The measured value is multiplied by –1/2”.

–A1/3: The measured value is multiplied by “–1/3”.

–A1/4: The measured value is multiplied by “–1/4”.

Note:

OFF

+A2

+A2/2

+A2/3

OFF

+A3

+A3/2

+A3/3

OFF

+A4

+A4/2

+A4/3

For AREA 2

For AREA 3

For AREA 4

OUTPUT MODE

OUT1

LASER ON

P. 1

+A1

OFF

OFF

OFF

AREA1

AREA2

AREA3

AREA4

100

AVERAGE

CAL-
CULATE

1 (0.833ms)

MEASUR-
ING MODE

SELF-TIMING
INTERVAL (ms)

NORMAL

DIGIT
SUPPRESS

NONE

ESC

HELP

NEXT

NOR

MAL

[CALCULATE] button

Advertising