Installation method

1

Fit the O-Ring included with the sensor unit to the
groove in the adapter as in the diagram on the right.

2

Connecting the sensor unit/adapter/piping
After installation, the body may be rotated horizontally to
330°. When rotating, hold the clasp in place with
something such as a wrench.

„

Throttle (OP-87311/87312)

For adapters other than the cheese adapter (OP-87286/87644), a separately sold throttle (Minimum width ø0.5 mm) to
lessen vibration and surge pressure can be installed. Especially for the GP-M100/M250/M400, installation of the
throttle is recommended.

OP-87311

(Corresponding adapter: OP-87280/87281/87282/87284/87285) is installed to the sensor unit

installation part (G3/4 female screw).

OP-87312

Corresponding adapter: OP-87283) is installed to the piping installation part (G1/4 female screw).

Install each with a flathead screwdriver. (Recommended tightening torque: 1.2 N•m)

„

Common precautionary points

• The recommended tightening torque when installing an adapter to the Sensor unit is 20 N•m.

It is recommended to apply grease to the G3/4 male screw part of the sensor main unit to prevent scorching.

• If the O-Ring is damaged it is possible that liquid will leak, therefore please purchase the following optional attachment.

O-Ring for the GP-M001/M010/M025:

OP-87287

O-Ring set for the GP-M100/M250/M400:

OP-87288

G1/4 female adapter (OP-87283) piping side O-Ring:

OP-87310

• When replacing the O-Ring, ensure that there is no debris on the surface to come in contact with the O-Ring.

Adapter for GP-M Series Precautionary Points When Installing

It indicates a situation which, if not avoided, could result in product damage as well as property damage.

Always use the O-Ring included with the sensor unit.

When using the G1/4 Female convertible
adapter (OP-87283), attach the O-Ring
included with the OP-87283 to the
groove of the piping connection part (the
G1/4 screw portion) of the adapter.

NOTICE

NOTICE

GP-M001/M010/M025

GP-M100/M250/M400

Included with

the sensor unit

(OP-87287)

Adapter

Included with

the sensor unit

(OP-87288)

Adapter

NOTICE

Sensor main unit

O-Ring

Adapter

(When using the OP-87281)

Piping

96M12124

1042-1