Connection method and diagrams, Precautions for safe use, Detection mode operation – KEYENCE AP-C30(P) Series User Manual

Page 2: Ap-ao1 panel mounting bracket, Caution, Analog output circuit

Advertising
background image

2

AP-AO1 Panel mounting bracket

SET

AP-C33

MODE

MP

a

SET

AP-C40

MODE

MP

a

Panel mounting ring

Panel-mounted sample

Front protective

cover

Panel-mounted sample

5. Connection Method and Diagrams

Insert the included connector-tipped cable into the sensor’s connector.

Position the connector so that the side of the connector where the metal-

lic contacts are visible is facing up.

Connector cable

Side where the metallic

contacts are visible faces up.

Input/output circuit

(AP-C30/C31/C33/C35)

(AP-C31P/C33P)

12 to 24 VDC

5 to 40 VDC

5 to 40 VDC

0V

Main cir

cuit

Ov
er

curr
ent

pr

ot

ection cir

cuit

Load

Load

Input/output

circuit

Analog output/

zero shift input: switchable

Brown

Blue

Black

White

Pink

12 to 24 VDC

0V

Main cir

cuit

Ov

er

curr
ent

pr

ot

ection cir

cuit

Input/output

circuit

Analog output/

zero shift input: switchable

Brown

Blue

Black

White

Pink

Load

Load

Analog output circuit

Analog

output (1 to 5 V)

0 V

Main

cir
cuit

Blue

Pink

Zero shift input circuit (NPN)

Zero shift input circuit (PNP)

(Short-circuit current 5 mA max.)

Main

cir
cuit

Blue

Pink

12 to 24 VDC

Main

cir
cuit

Pink

(Short-circuit current 5 mA max.)

Brown

Use non-contact input device such as open-collector.

6. Precautions for Safe Use

Follow these guidelines. Failure to do so may result in product damage.

CAUTION

Connections

Input/output circuit

Always ground the frame ground terminal when using an off-the-

shelf switching regulator.

Use separate conduits for power line and high voltage lines, since

use of a common conduit may result in device malfunction.

Improper wiring may result in the device becoming excessively hot

or in device damage.

Other

Do not use this sensor with corrosive gasses or liquids.

Do not insert objects such as wire into the pressure insertion area.

Doing so may result in the device failing to operate properly due to
damage to the pressure-sensitive elements.

Do not use sharp-tipped objects to press the setting keys.

7. Detection Mode Operation

General-purpose mode (F-1)

This mode allows the user to configure 2 detection points.

Control output 1: Turns ON when pressure exceeds setting P1.

Control output 2: Turns ON when pressure exceeds setting P2.

<Output 1>

P1

0

Output 1 OFF

ON

OFF

P2

0

OFF

ON

OFF

<Output 2>

Output 2

* Hysteresis is a standard 0.5% of F.S. when operating in general-purpose

mode and application modes 1 and 2. During focus mode operation, it is

0.2% of F.S.

Variable hysteresis mode (F-2)

Two detection points may be user-configured, and hysteresis for both

may also be set.

Control output 1: Turns ON when pressure exceeds setting P1. Turns OFF

when pressure drops the selected hysteresis amount

below P1.

Control output 2: Turns ON when pressure exceeds setting P2. Turns OFF

when pressure drops the selected hysteresis amount

below P2.

<Output 1>

P1

H1

Output 1

OFF

ON

OFF

0

P2

OFF

ON

OFF

H2

0

<Output 2>

Output 2

Window mode (F-3)

The user may select a pair of upper (Hi) and lower (Lo) thresholds,

and the sensor turns OFF when the pressure falls outside of the result-

ing range.

* Control output 1 is a standard 0.5% of F.S. During focus mode opera-

tion, it has a hysteresis of 0.2% of F.S., and control output 2 has a

hysteresis of 0.

Hi

Lo

Output1/Output2 OFF ON

ON

OFF

OFF

<Output 1/Output 2>

0

Application mode 1 (A-1)

This detection mode is optimum for use in suction detection applica-

tions.

Recommended sensor heads: AP-C30/C31/C31P

Control output 1: Suction pressure detection.

Turns ON when pressure exceeds setting P1.

Control output 2: Detection and confirmation of vacuum burst pressure

detection (or vacuum ultimate pressure).

Turns ON when the pressure falls below setting P2.

* Cannot be used to detect vacuum burst pressure with

the AP-C31/C31P when operating in focus mode.

Standard mode operation only.

Zero shift:

The zero point is shifted immediately after the zero

shift timer is set following the activation of zero shift

input.

P1: Pressure setting for control output 1.

T1: Zero shift timer setting (ms) < Variable between 0 and 1,999 ms

P2: Pressure setting for control output 2.

* P2 is unrelated to zero shift and is always based on the current ambi-

ent pressure.

Application mode 2 (A-2)

This mode is optimum for use in leak test applications.

Recommended sensor head: AP-C33/C33P

Control output 1: Leak pressure detection.

Turns ON when pressure falls below setting P1.

*Output only when receiving zero shift input.

Control output 2: Window comparator output for detection of fill pressure.

Turns OFF when pressure falls outside the range deter-

mined by upper (Hi) and lower (Lo) thresholds.

* Fill pressure values are displayed with the center pres-

sure as 0 during focus mode operation.

P1: Pressure setting for control output 1.

Hi: Upper threshold setting for control output 2.

Lo: Lower threshold setting for control output 2.

* The Hi and Lo values are unrelated to zero shift and are always based

on the current ambient pressure.

<Output 1>

P1

Output 1 OFF

ON

OFF

0

<Output 2>

0

Output 2 OFF

ON

OFF

P2

0

0

Shift

Zero shift input

T1

<Zero shift>

<Output 1>

P1

Output1

Zero shift input

OFF

ON

OFF

ON

0

<Output 2>

Hi

Lo

Output 2 OFF

ON

OFF

OFF

ON