KEYENCE AP-C40(P) Series User Manual

Instruction manual, Ap-c40(p) series, Digital pressure sensor with 2-color display

Advertising
background image

1

Digital Pressure Sensor
with 2-Color Display

AP-C40(P) Series

Instruction Manual

1. Safety Precautions

WARNING

Do not use this product in safety circuits such as those designed to
protect human workers.

This product does not employ an explosion-proof construction. Do not
use it in the presence of flammable gasses, liquids, or powders.

This is a direct current power supply type sensor. Application of an
alternating current may result in explosion or fire.

Accessories

96M1402

3. Sensor Head Installation

1 connector cable (2 m)

1 unit scale label

2. Part Names

SET

AP-C40

MODE

MPa

1

2

Pressure display units

*Apply the units sticker here.

Pressure display

Mode button

Manual adjustment button

Set button

Wiring

connector

Sensor head

connector

Mounting screws
(M3 x 2)

Operational indicator /
Output 1, Output 2

1

2

1 instruction manual

1) Cut the cable to an appropriate

length and strip away about 25
mm of the outermost insulation.

Note: It is not necessary to

remove insulation from the
core wires.

2) Insert the cables after aligning

them with the colors on the seal
on top of the connector body.

About

25 mm

About

25 mm

Connector
body

Connector

cover

Connector
lock

Orange

Brown Blue

Gray

Pressure

connection

3) Press together the body and the

connector cover into which the
cables were inserted to make a
connection (use a pair of pliers
or similar tool to press them to-
gether).

4) Insert the sensor head connec-

tor into the hole of the amp unit.
To remove the connector, de-
press the connector lock and
pull it out.

* Do not reuse sensor head

connectors that have already
been pressure-connected.

Insert until you hear a
clicking sound.

4. About Sensor Head Installation

Common

Do not subject the case to pressure sufficient to deform
its shape during installation.

AP-41(M) •

Use a torque of 0.3 N

m or lower to tighten the screws

43 • 44

for the sensor head conduits.

AP-48

Use a torque of 5 N

m or lower to tighten the screws for

the sensor head conduits.
Take care that no foreign objects enter the sensor when
opening one of the pressure ports to atmospheric air.
Take care not to bend the pressure ports.
Connect the “High” port to the high-pressure side of the
system and the “Low” port to the low-pressure side.

5. Mounting Brackets (option)

Dedicated mounting hardware is available for the sensor, allowing it to be
installed in a range of locations.

Horizontal mounting bracket

Wall mounting bracket

(AP-BO1)

(AP-BO2)

Faceplate/ceiling mounting bracket

Tilted mounting bracket

(AP-BO3)

(AP-BO4)

1 sensor head connector