2 specifications, Specifications, Specifications -3 – KEYENCE GL-RHG Series User Manual

Page 111

Advertising
background image

7-3

GL-RHG-M-NO7-E

Sp
ecification

s and

Dim

ensio

ns

7

7-2

Specifications

Specifications

*1 When the GL-RHG is used under surrounding air temperatures between 50 to 55°C, the Maximum

load current should not exceed 350 mA.

Model

GL-RHG

Beam axis spacing/Lens diameter

20 mm/5

Detection capability

25 mm

Operating distance

0.2 to 15 m

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m (9.84 ft.) or more)

Light source

Infrared LED (870 nm)

Response time

Optical synchronization (Channel 0) or Wire synchronization: 6.6 to 14.8 ms

Optical synchronization (Channel A or B): 6.9 to 22.0 ms

"Response time (OSSD)" (page 7-5)

OSSD operation

Turns on when no interruptions are present in the protective zone

Synchronization between the
transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-RHG systems.

Optical synchronization: prevented by Channel A and B with setting switch

Wire synchronization: prevented automatically

Control output
(OSSD)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA

*1

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m (16.4 ft.))

OFF state voltage

Max. 2.0 V (with a cable length of 5 m (16.4 ft.))

Leakage current

Max. 200 A

Max. capacitive load

2.2 F

Load wiring resistance

Max. 2.5 

Supplemental
output
(Non-safety-
related output)

AUX

Transistor outputs. (Compatible with both PNP and NPN)

Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m (16.4 ft.))

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W) or

LED lamp (load current :10 to 230 mA) can be connected

Input

EDM input

< with PNP cable >

ON-voltage: 10 to 30 V

OFF-voltage: Open or 0 to 3 V

Short-circuit current: Approx. 2.5 mA

(Approx. 10 mA for EDM)

< with NPN cable >

ON-voltage: 0 to 3 V

OFF-voltage: Open or
10 V to Power voltage

Short-circuit current: Approx. 2.5 mA

(Approx. 10 mA for EDM)

Wait input
Reset input
Muting input 1, 2
Override input

Power supply

Power voltage

24V DC ± 20% (Ripple P-P 10% or less, Class2)

Current consumption

Transmitter: 43 to 81 mA, Receiver: 66 to 91 mA

"Current consumption" (page 7-6)

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Environmental
resistance

Enclosure rating

IP65 / IP67 (IEC60529)

Overvoltage category
Ambient temperature

-10 to +55°C (No freezing)

Storage ambient
temperature

-25 to +60°C (No freezing)

Relative humidity

15% to 85%RH (No condensation)

Storage relative humidity

15% to 95%RH

Ambient light

White incandescent lamp: 3,000 lx or less, Sunlight: 20,000 lx or less

Vibration

10 to 55 Hz, 0.7 mm compound amplitude, 20 sweeps each in X, Y and Z directions

Shock

100 m/s

2

(Approx. 10 G) 16 ms pulse in X, Y and Z directions 1,000 times each axis

Material

Main unit case

Aluminum

Upper case/Lower case

Nylon (GF30 %)

Front cover

Polycarbonate, SUS304

Weight

See "Weight" (page 7-6)

Approved
standard

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)

IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)

IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)

EN ISO13849-1:2008 (Category 4, PL e)

UL508

UL1998

GB4584

Construction code for safety device for press machine and shearing machine