background image

2-11

Temporary Suspension of Safety Function

2-35

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

(11) Turn OFF the muting input 1.
(12) For the number of 3rd digit to 1st of password, perform the same procedure of (9) to (11).

If you set the password of "0000", SL-V goes back to the point after the step (8) is completed.
(SL-V does not accept the password of "0000".) Therefore, you must set another password again.

(13) When the step (12) is completed (this means all digits have been set.) all of the function indicators

(MUTE1, MUTE2, OSSD, INTER LOCK) on the receiver light up for approx. 2 seconds before the SL-
V goes back to the I/O monitoring mode.

Ex.: Time chart when setting the password of "0123"

Steps (2) to (8)

Steps (9) to (12)

Number

5

6

7

8

9

Bar LED

5

4

3

2

1

5

4

3

2

1

5

4

3

2

1

5

4

3

2

1

5

4

3

2

1

Approx. 4.5 s

ON

OFF

SL-V

A

A

A

A

A

A

A

A

A

A

A

A

A

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Muting input 1

ON

OFF

Muting input 2

ON

OFF

A: 20 ms or more, B: 40 ms or more

(2)

Continued below

(3)

(5)

(6)

(8)

(7)

(4)

ON

OFF

SL-V

A

A

A

B

B

A

A

A

A

A

B

B

Muting input 1

ON

OFF

Muting input 2

ON

OFF

A

A

A

A

A

A

A

A

4th

Set to "0"

3rd

Set to "1"

2nd

Set to "2"

1st

Set to "3"

A: 20 ms or more, B: 40 ms or more

Continued
from above

(8)

(10)

(9)

(11) (12)

Cable

Self-diagnosis

Series Connection

Interlock

AUX

EDM

Wait

State Information

Alert

Clear/Blocked

Suspension

Fixed

Reduced

Monitoring