English – KEYENCE SL-R12EX User Manual

Page 53

Advertising
background image

Chapter 4 Wiring and setting

4-15

4

ENGLISH

4-5-3 Setting procedure for two-input muting function

1. Connect the 2 muting devices and the muting lamp

(SL-R12D or similar lamp) to the SL-R12EX. See “4-
5-1 Muting devices” (

4-10) and “4-5-2 Muting

lamps” (

4-12) for more information.

2. Turn OFF the power to SL-R12EX and turn ON the

function switch 5. Two function switches having the
same number are provided on the SL-R12EX. You
must turn ON both switches. All other switches
should be OFF.

3. Set the PROGRAM switch to the “PROG” side.

4. Turn ON the power to the SL-R12EX and confirm that the “TEACHING” LED blinks. If the

“TEACHING” LED does not light, repeat this procedure from Step (1).

5. Press the “SET/TEACH” button once more and release it. Confirm that the “TEACHING” LED

turns OFF.

6. Set the PROGRAM switch to the “RUN” side.

7. The 2-input muting function can be carried out and begin operation when you turn OFF the

power to the SL-R12EX and then back ON, or when you activate the restart input on the SL-R11
(see the SL-R11 Instruction Manual for more information about restart input).

8. See “2-5-2 Two-input muting” (

2-8) for information about function operation.

SET/TEACH PROG

RUN

TEACHING

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

TEACHING

SET/TEACH

Function switches

(UP for ON; DOWN for OFF)

PROGRAM

SWITCH

Advertising