2 specifications, 3 external dimensions, Specifications – KEYENCE SJ-F036 User Manual

Page 8: External dimensions, Body ■ ac adapter, Body, Mounting fixtures ■ ac adapter (sj-u2)

Advertising
background image

8

5-1

Timing Charts

Condition alarm output timing chart

Alarm output timing chart

Power

ON

OFF

Static elimination
stop input

ON

OFF

Alarm indicator

Blinking

OFF

Alarm output
(N.C.)

ON

OFF

Ion emission

Emitting

No
emissions

Condition
indicator

Blinking

OFF

Condition alarm
output (N.O.)

ON

OFF

When the condition alarm is output,
removing the cause of the alarm can
restore the normal state. One way of
restoring the normal state is to
enhance the installation
environment.

Max. 6.5 s

Power

ON

OFF

Alarm indicator

ON

OFF

Static elimination
stop input

Blinking

OFF

Alarm output
(N.C.)

ON

OFF

Ion emission

Emitting

No
emissions

When the alarm is output, the
normal state can be restored by
performing one of the two available
restore methods depending on the
cause of alarm output.

For details on how to restore the
normal state, see "During an
alarm (levels 1, 2)" (page 9).

Max. 6.5 s

5-2

Specifications

Body

AC adapter

Static elimination stop input

Alarm output

Ion level alarm output

Condition alarm output

Power voltage

Current consumption

Operating ambient temperature

Operating ambient humidity

Voltage application method

Applied voltage

Ion balance control method

Static elimination time

*1

Ion balance

*1

Max. fan speed

*2

Max. blow rate

Ozone concentration

Control input

Variable DC

±7000 V max.

I.C.C. method

3.1 m

3

/min

0.005 ppm max.

NPN open collector or no-voltage contact signal

NPN open collector

100 mA (40 V max.)

24 VDC±10%

1.2 A max.

0 to +50°C

35 to 65%RH (condensation not allowed)

Approx. 620 g

Approx. 2 sec

±5 V

0.8 m/s

Approx. 0.7 sec

±10 V

3.5 m/s

Model

Control output

Rating

Environmental
resistance

Weight

*1 Values obtained by measurement 300 mm from the front of the Static Elimination Blower

(SJ-F031: Blow rate min./SJ-F036: Blow rate max.)

*2 Values obtained by measurement 300 mm from the front of the Static Elimination Blower

SJ-F031

SJ-F036

Rated input

Rated output

Operating ambient temperature

Operating ambient humidity

* The power cable supplied with SJ-U2 is 125V rated power voltage.

100 to 240 VAC (50/60 Hz)

24 VDC 2.65 A

0 to +35°C

20 to 80% (condensation not allowed)

Approx. 250 g

Model

Rating

Environmental
resistance

Weight

SJ-U2

5-3

External Dimensions

Body

Static Elimination Blower and mounting fixture

Static Elimination Blower

126

11

0

181

106

(5)

2x2 M4 to depth 6

12.2

1

1.7

45

64.5

SJ-F031 61.5
SJ-F036 66.5

5.5

(50)

1

(121.6)

158

87

120

(Fixing part 121)

5-3

External Dimensions

Mounting fixtures

AC adapter (SJ-U2)

R35

4.5

3-M6

80°

30°

26

121

2.3

35

50

110

138

70

10

4.5

5.5

17

t = 3.2

60

4.5

98.5

83

5.5

40

40°

Mounting fixture (OP-84374)

Ceiling-mounting fixture (OP-78477)

(37.5)

7

ш16

(10.3)

(16.3)

(12.5)

(14)

28

ш3.5

1800

114.5

50.5

Advertising
This manual is related to the following products: