Command processing flow – KEYENCE CV-X Series User Manual

Page 10

Advertising
background image

www.keyence.com

KEYENCE CORPORATION. Vision System Division

‐ 10 ‐

Command Processing Flow

To control the controller via PLC‐Link, use the number‐specified commands.

1

Refer to "Control/Data Output via Commands" in the user's manual to check the commands to use and the
formats of the number-specified commands.

Here is an example of using the PW command (command No. 24) that switches the program setting.

The following must be specified to execute the PW
command:
Command No. (24)
SD card No. (d) of the switch target program setting
Setting No. (nnn)
Specify 2‐word integer values from the data memory
specified as the "Command Address" in order.

The command processing result is stored to the address
specified as the "Command Result Address".