Saving images – KEYENCE SR-750 Series User Manual

Page 47

Advertising
background image

47

E SR-750 UM

I/O

„

Input Terminal Common

• Input polarity

Sets the input polarity of the IN terminal.
Default

: Norm. open

Setting range : Norm. open or Norm. close

• Required input duration

Sets the required input duration for the IN terminal.
Default

: 2 ms

Setting range : 1 ms, 2 ms, or 10 ms

„

IN1/2 Terminal

• Function

Sets the function for the IN1/2 terminal.
Default

: IN1 terminal…Timing input
IN2 terminal…Preset input

Setting range : Disable, TIMING, Preset Input, TEST, Clear PLC link error,

TUNING

• Test mode

When "TEST" is selected, specify the test mode to start.
Default

: Reading rate test

Setting range : Reading rate test, Read time test, or Positioning test

• Startup state

Sets whether to activate the input function specified for the IN1 and IN2 terminals
at power-on.
Default

: Disable

Setting range : Disable or Enable

• IN LED synchronization

Set whether to synchronize with IN LED.
Default

: IN1…Enable

IN2…Disabled

Setting range : Disable or Enable

„

Output Terminal

• TRG BUSY Output at Power On

Set this option to enable TRG BUSY output upon reader startup.
Default

: Enable

Setting range : Disable or Enable

• Output duration

Sets the output ON duration for the OUT terminal.
Default

: 500 ms

Setting range : 10 to 2550 ms

• OUT1/2/3 function

Sets the function for the OUT1/2/3 terminal.
Default

OUT1…OK

OUT2…NG (Comparison NG), ERROR
OUT3…TRG, LOCK, MODE, ERR BUSY

Setting range : OK, NG (Comparison NG), ERROR, STABLE, UNSTABLE,

PRESET OK, TUNING OK, TRG BUSY, LOCK BUSY, MODE
BUSY, ERR BUSY, FILE BUSY or EXT.LIGHT

• External light output polarity

Sets the output polarity of the EXT.LIGHT signal.
Default

: Norm. open

Setting range : Norm. open, Norm. closed

Saving Images

• OK image

Sets the saving option for images successfully read.
Default

: Disabled

Setting range : Disabled or Send by FTP

• Comparison NG

Set save destination for comparison NG image.
Default

: Disable

Setting range : Disabled or Send by FTP

• Error image

Sets the save destination for read error images.
Default

: Save to RAM

Setting range : Disabled, Save to RAM, Save to ROM, or Send by FTP

• Unstable image

Sets the save destination for unstable images.
Default

: Disable

Setting range : Disabled or Send by FTP

• Target burst number

Default

: All banks

• Captured image

Sets the saving option for captured images.
Default

: Save to RAM

Setting range : Save to RAM or Send by FTP

• Image Save Mode

Sets the image saving mode.
Default

: Save final bank image

Setting range : Save final bank image, Save specified number of images after

timing ON, or Save specified number of images after timing OFF

• Number of images to save

Sets the number of images to save after the timing ON/OFF.
Default

: 10 images

Setting range : 1 to 10 images

• Edit image file name by script (FTP transmission only)

Sets the edit image file name function.
Default

: Disable

Setting range : Disable or Enable

„

FTP Settings

• IP address

Sets the IP address of the remote FTP server.
Default

: 0.0.0.0

Setting range : 0.0.0.0 to 255.255.255.255

• User/Password

Sets the user name/password of the destination required for FTP client
operations.
Default

: User…admin

Password…admin

Setting range : Up to 16 characters

Set in ASCII characters.

• Passive mode

Set this option to send passive commands to the remote FTP server.
Default

: Disable

Setting range : Enable or Disable

• Change directory

Set this option to change FTP remote directory.
Default

: Disabled

Setting range : Disable or Enable

• Format

Sets the image format sent via FTP.
Default

: JPEG

Setting range: JPEG, Bitmap

• JPEG quality

Default

: 5

Setting range : 1 to 10

• Binning

Default

: 1/4

Setting range: Full, 1/4, 1/16, 1/64

• Directory name

Sets the remote directory.
Default

: image

Setting range : 1 to 32 characters