CONNECTION AND WIRING

„

Power supply connections

Connect the 5 V DC power supply to the power supply connector of the
BL-600 Series.

CAUTION

• Be sure to match the polarities of the power supply when

soldering the connections. Reversing the polarities will damage

the unit.

• Make sure that the power supply provides a stable 5 V DC ± 5%. If

the power supply does not function in the above range, it can

damage the unit.

• Do not extend the power cable. A long power cable can cause a

voltage drop, preventing the BL-600 from starting properly.

Note: Use a power supply with Class 2 output defined in NFPA70 (NEC:

National Electrical Code) when using this product as an UL/C-UL
certified product.

„

Trigger input

The trigger input is used to signal the BL-600 to start reading (start laser
emission).
The trigger input is a non-voltage input (TTL input is also available with
negative logic).

„

OK/NG output

The OK/NG output is used to display the comparison/verification result
of the preset and readout data. When no preset data is registered, it can
be used to display whether or not bar codes are being read correctly.
The output form is NPN open-collector.

„

RS-232C connection

Wire the RS-232C as indicated below when connecting the BL-600 to a
PC.

MOUNTING ANGLE AND POSITION OF THE BL-600 SERIES

Normally, the BL-600 Series provides the best reading stability when
mounted at the following angle and distance.

* The supplied mounting bracket facilitates the angle setting.
* The reading rate check mode ensures an optimal reading position.

Ö

Refer to User’s manual

* The laser beam application angle for the BL-650HA/651HA is 17° ±3°

with reference to a line perpendicular to the rear surface of the unit.

Note 1: Do not mount the BL-600 Series so that the laser beam is
applied to bar codes at a right angle (

±

10°). Otherwise, the specular

reflections may cause unstable reading or reading errors.

Note 2: The reading distance and angle may vary depending on the
narrow bar width, size, and printing quality of bar codes. Be sure to test
the BL-600 Series’ ability to read the actual bar codes in test mode.

5 V DC

BL-600

+5V

9

GND

5

+

GND

TIM

1

5

5 V DC

10 k

Ω

4.7
k

Ω

Internal circuit

BL-600

Contact or
solid-state

GND

OK/NG

4/6

5

Load

BL-600

10 k

Ω

* Rated load: 24 V DC
(30 mA) max.

+

Internal circuit

3

2

8
7
5
9

BL-600

SD
CS
RS

GND

+5V

PC

2
3
4

7
6

5

20

SD

RD

RD
RS
CS
SG
DR
ER

D-sub 25-pin (male)

M2.6 screw

D-sub 9-pin (male)

# 4-40 screw

2

3

7

8

5

9

PC

SD

RD

RS

CS

GND

+5V

3

2

8

7

5

4

6

SD

RD

CS

RS

SG

ER

DR

+

BL-600

D-sub 9-pin (female)

# 4-40 screw

D-sub 9-pin (male)

# 4-40 screw

Connecting the computer with 9-pin

Connecting the computer with 25-pin

BL-600/601/600HA/601HA

BL-650HA/651HA

Reading distance

15°

17°

Reading distance

Reading distance

BL-600/601: 120 mm

BL-600HA/601HA: 90 mm

Reading distance

BL-650HA/651HA: 65 mm

Within ±10°

Within ±10°

Incorrect

Incorrect

BL-600/601/600HA/601HA

BL-650HA/651HA