Ld3xi/ld3xic general installation – Kistler-Morse KM LD3xi Load Cell User Manual

Page 16

Advertising
background image

Chapter 3. LD3xi/LD3xiC Mounting

3-2

This section describes the installation procedures for the following
hardware options:

Universal Top Plate Adapter, Leveling Top Plate Adapter, Anyadapter
Plate, Leveling Base Adapter Plate as well as the LD3xiC.

LD3xi/LD3xiC
General Installation

1.

Prior to installing the load cell, verify that they are the correct
capacity for your application by reviewing the information on
the label.

2.

Measure the load cell voltage output. With no-load,
the meter should read 0mV. (This measurement range is used
only to verify the condition of the Load Disc.)
If the reading is significantly outside of this range, consult the
factory before continuing the installation.

Note: Concrete founda-
tion and grouting shown
for reference only. The
concepts apply to all
foundation types.

Anchor bolts supplied by
customer.

Figure 3-1: Angular misalignment

3.

Place bolt through center hole of adapter plate and install
hardware for your application (See Appendix D: TI Drawings)

a.

For Universal Top Plate Adapter, install bolt and
plate to LD3xi, tightening bolt to 5-10 ft-lbs.

b.

For Leveling and Anyadapter, install washers and
nuts to the bolt and plate, making sure the washers/
nuts are loosely tightened against plate. Install the
plate assembly to the LD3xi, tightening bolt to 5-10
ft-lbs.

4.

For Leveling and Anyadapter applications, adjust plate to
lowest position by lowering jam nut to top of LD3xi and
tighten. Then lower leveling nut to the jam nut.

(If you have the LD3xiC, go to Step 5.)