Installation Warning Statements

This section includes the basic installation warning statements. Translations of these warning
statements appear in the Regulatory Compliance and Safety Information for the Catalyst 2960 Switch
document that shipped with the switch.

Warning

To prevent the switch from overheating, do not operate it in an area that exceeds the
maximum recommended ambient temperature of 113°F (45°C). To prevent airflow
restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.
Statement 17B

Warning

This equipment is intended to be grounded. Ensure that the host is connected to earth
ground during normal use.
Statement 39

Warning

Class 1 laser product. Statement 1008

Secure the Switch on a Desk or Shelf

This section describes installation information specific to the Catalyst 2960-8TC and Catalyst
2960G-8TC switches. For information applicable to the other Catalyst 2960 switches, see the
Catalyst 2960 Switch Hardware Installation Guide on Cisco.com.

To place the switch on a desk without using the mounting screws, simply attach the four rubber feet
on the bottom panel of the switch.

To secure the switch on top of or under a desk or a shelf, or on a wall, use the mounting template and
three mounting screws. Follow these steps:

1.

Position the screw template on the mounting surface with the two side-by-side slots forward. Peel
the adhesive strip off the bottom, and attach the template (see Figure 1).

2.

Use a 0.144-inch (3.7 mm) or a #27 drill bit to drill a 1/2-inch (12.7 mm) hole in the three template
screw slot positions.

3.

Insert the screws in the slots on the template, and tighten until they touch the template. Remove
the template from the mounting surface (see Figure 1).