A&D Weighing AD-8527 User Manual

Cancel (+) quick usb adapter ad-8527, Quick usb adapter ad-8527 cancel (+), Ad-8527 quick usb adapter instruction manual

Advertising
background image

-1- -2- -3-

USB extension cable


RS-232C cable

with a D-Sub 9-pin connector


RS-232C cable

with a D-Sub 25-pin connector

RS-232C cable

with a 7-pin DIN connector

CANCEL

(+)

Quick USB Adapter

AD-8527

AD-8527

Quick USB Adapter

Instruction Manual










© 2009 A&D Company, Limited. All rights reserved.

No part of this publication may be reproduced,
transmitted, transcribed, or translated into any language
in any form by any means without the written permission
of A&D Company, Limited.

The contents of this manual and the specifications of the
instrument covered by this manual are subject to change
for improvement without notice.

1WMPD4001958A

Using the AD-8527

When operating this instrument, be sure to observe the
following:

Caution

Do not open the case to repair the AD-8527. Only
qualified personnel can do that. Attempting repairs
yourself may cause damage to the AD-8527. Damage
caused by attempting to do the repair yourself will void
the warranty

.

Precautions on Usage

Caution

With the cap attached over the connectors, the
AD-8527 is protected against water splashing
(equivalent to IP65). Please note that it will not endure
immersion in water or high pressure running water.

The AD-8527 is supplied power and is turned on only
when it is connected to a weighing instrument or the
USB of a personal computer.





1. Introduction

This manual describes how the AD-8527 works and how to get
the most out of it in terms of performance. Please read this
manual completely before using the AD-8527.

2. Features

• When connected to the RS-232C interface of a weighing

instrument and to a personal computer using USB
simultaneously, the AD-8527 can transmit the weighing data
that the weighing instrument outputs in real time to the personal
computer. This enables a personal computer without COM
ports to receive data.

• The AD-8527 functions similar to a USB keyboard. Thus, no

software installation such as a driver is not necessary. Once
connected as described above, the weighing data can be
transmitted to the personal computer.
Note that Command transmission from the personal computer
to the weighing instrument is not available.

• The AD-8527 can transmit the data to any application such as

Excel, Word and Notepad for Windows.

• As power is supplied to the AD-8527 from the weighing

instrument or USB, no special power source is required.

• The AD-8527 has no data storage function. To store data

without using a personal computer, use the AD-1688 Weighing
Data Logger.

Note: The AD-8527 is supplied power and is turned on only

when it is connected to a weighing instrument or the
USB of a personal computer.



3. Unpacking

When unpacking, confirm that everything is contained.

AD-8527 Quick USB Adapter

USB extension cable (0.5 m)

RS-232C cable with a D-Sub 9-pin connector (1 m) : AX-KO3571-100

RS-232C cable with a D-Sub 25-pin connector (1 m) : AX-KO3572-100

RS-232C cable with a 7-pin DIN connector (1 m)

: AX-KO3573-100

Instruction manual (this document)


When the AD-8527 is in use, the cap

can be attached on the bottom.




Each side has an opening. Use the
openings as follows.

A: Attach a strap to carry.
B: Connect the cap and the main unit

so that the cap will not be lost.


4. Connection and Key Operations
















Key

When pressed

(To press and

release immediately)

When pressed and held

(To keep pressing

for 2 seconds or more)

SET

Displays the date and

time.

Displays the function setting

menus.

(+) None

Starts or stops data transmission

at a set interval.

(Only in the interval mode)

CANCEL

None

None


5. Displaying the Date and Time

At the standby display, press the SET key to display the year, date

and time.


1. Standby display


2. The display indicates the year and date for 2 seconds each,

and then indicates the time.



3. Press any key to return to the standby display.

6. Setting the Date and Time

Note: The date and time were set to the Japanese

standard time at the factory when shipped. Before
use, set the date and time to your local time.

Change the date and time as follows.


1. Refer to “5. Displaying the Date and Time” to display the date

and time.
When the year, date or time is displayed, press and hold
the SET key for 2 seconds or more. The display flashes
and the AD-8527 enters the setting mode.

Using the following keys to set the date and time.

(+) key:

Increase the value by one

CANCEL key: Decrease the value by one

When the above keys are held pressed, the
value is increased or decreased continuously

SET key:

Confirm the setting and go to the next item.

2. After setting the year, month, day, hour and minute, press

the SET key to return to the standby display.











7. Transmitting the Weighing Data

Transmitting data from a weighing instrument to a personal
computer.
1. Connect the AD-8527 to the USB port of a personal

computer and connect the AD-8527 to a weighing
instrument using the RS-232C cable.

Note: Use the cable appropriate to the RS-232C

connector of the weighing instrument.

Power is supplied to the AD-8527

and the standby display appears.

If either USB or RS-232C is not

connected, “- - - -“ appears.

2. Press the PRINT key of the weighing instrument to

transmit the data to the AD-8527.

Then, the AD-8527 transmits the data to

the personal computer as keyboard input
signals. When transmitted, a buzzer sounds
and “out” appears for about 2 seconds.

Note: If data is not input into Excel correctly, refer to

“10.2. If the Data Fails to be Input into Excel
Correctly”.
When transmitting GLP output and statistical
results, set the weighing instrument “Data
output pause (
pU5e)” to “Pause (1.6 seconds)”.

3. Repeat step 2 as necessary.
4. Disconnect the weighing instrument from the AD-8527.

5. Disconnect the personal computer from the AD-8527.

USB connector

RS-232C connector

Display

(+) key

SET key

CANCEL key

Press

Personal

computer

USB cable

RS-232C

cable

AD-8527

Weighing instrument

Cap

AD-8527

RS-232C

connector

OK

DATE

DATE

OK

OK

DATE

DATE

DATE

Continued to the reverse side

Quick USB Adapter

AD-8527

CANCEL

(+)

CANCEL

(+)

Quick USB Adapter

AD-8527

B

A

Quick USB Adapter

AD-8527

CANCEL

(+)

Standby display

OK

OK

Quick USB Adapter

AD-8527

CANCEL

(+)

Advertising