DynaPure

®

Oil Mist Collector

Installation, Operation, and Maintenance Instructions

Better Air is Our Business

®

Table of Contents

1.0 Description

2.0 Unpacking

3.0 Drain

4.0 Operation

5.0 Installation

5.1 General
5.2 Prefilter
5.3 Final Filter

6.0 Maintenance

6.1 General
6.2 Throwaway Liner Replacement
6.3 Cleaning Procedure - Size A-1
6.4 Cleaning Procedure - Sizes AS-100 and Larger
6.5 Motor Replacement - Size A-1
6.6 Motor Replacement - Sizes AS-100 through AS-1000
6.7 Prefilter Pad Replacement

7.0 DynaPure Parts List

1.0 Description

The DynaPure

®

filter is designed to remove particles of mist from

contaminated air and discharge clean air to the atmosphere. The filter
draws in contaminated air and removes the mist by the spinning
action of the drum and filter elements. The collected particles are
discharged as a liquid through the drain, and the cleaned air is
exhausted through the outlet.

2.0 Unpacking

Inspect the shipping carton carefully for damage. If the carton is
intact, open it and check the unit for damage. Remove the unit from
the carton. Notify your shipping agent if there was any damage
during shipment.

3.0 Drain

Sizes larger than A-1 are equipped with a 1" NPT drain connection
which may be piped directly to the oil sump, allowing filtered oil to
drain into the sump and be reused. If the mist generated contains
undesirable elements, it may be collected in any suitable container.
Drain should not be trapped, reduced in size, or have an elbow
connection at the drain connection.

4.0 Operation

It is recommended that the unit be run continuously during the hours
of plant operation as intermittent cycling may cause unnecessary
loading of the motor, reducing its service life.

The DynaPure should continue to be operated at least twenty
(20) minutes after the machine being exhausted is shut off.
This
will allow time for the unit to purge itself of oil.

5.0 Installation

5.1 General
Model A-1 must be installed vertically using the threaded inlet opening
for mounting. The A-1 drains back through the inlet, eliminating
separate drain piping or inlet ducting. On sizes larger than A-1, the
base is pre-drilled for mounting. Units should be as close as possible
to the point of mist generation. Try to keep the length of hose to a
minimum, preferably less than eight feet. Cut the proper length of
hose required to connect the inlet of the filter to the outlet of the
pickup duct or hood. Avoid excessive sagging which would form a
trap. Clamp the hose to the filter and pickup duct or hood, making
sure there are no air leaks.

CAUTION

ROTATION MUST BE CLOCKWISE WHEN LOOKING INTO INLET.