ECS and CXT-E Retrofit Instructions Kit # 27004-TAB

Technical Instruction Document

TID-0141_0A

12/30/2014

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288 Page 68 of 76

INTRODUCTION

The information included in this Appendix lists optional items which may vary, depending on:

• Type of Water Heater being retrofitted
• Required Water Heater flow rate
• Type of Control Valve Actuator previously installed
• Control Valve size

Table B-1 and the Tables/Appendices referenced therein, list the applicable items included in the
Retrofit Kit for the specific Water Heater being retrofitted.

TABLE B-1. ECS RETROFIT KIT OPTIONAL ITEMS

ITEM

DESCRIPTION

LOCATION ON UNIT

QTY.

REFERENCE

TABLE/APPENDIX

1

Orifice Disc

Cold Water Inlet

1

Table B-2

2

Compound Pressure Gauge
(Steam-to Water Units ONLY)

Steam Inlet to Heater

1

Table B-3

3

Valve Flange Gaskets
(2.50” to 4.00” Valves ONLY)

Control Valve Inlet &
Outlet Flanges

2

Table B-4

4

Pneumatic or Electro-Hydraulic
Actuator Replacement Kit

Control Valve

1

Appendix C

5

Self-Contained Actuator
Replacement Kit

Control Valve

1

Appendix D

TABLE B-2. ORIFICE DISC OPTIONS (Table B-1, Item 1)

AERCO

PART NO.

QTY

WATER HEATER

FLOW RATE (GPM)

APPLICABLE UNITS

49032-1

1

0 – 45

B-Plus, B-Plus II, E-Plus

49032-2

1

0 – 70

B-Plus, B-Plus II, E-Plus

49032-3

1

0 – 125

B-Plus, B-Plus II, E-Plus

49032-4

1

> 125

B-Plus, B-Plus II, E-Plus

49032-5

1

0 – 45

A-Plus, WWDW-24

49032-6

1

0 – 70

A-Plus

49032-7

1

0 – 100

WWDW-45, WWDW-68

49032-8

1

0 – 45

WWDW-45, WWDW-68

49032-9

1

0 – 125

WWDW-45, WWDW-68

49032-10

1

> 125

WWDW-68