Figure 2.1, Installation procedures – AERCO KC1000 Heater w/Mod-Box Controller User Manual

Page 7

Advertising
background image

INSTALLATION PROCEDURES

2

SECTION 2 - INSTALLATION PROCEDURES

2.1 RECEIVING THE UNIT

Each KC unit is shipped as a single crated unit.
The shipping weight is approximately 1500 lb.
and must be moved with the proper rigging
equipment for safety and to avoid damages.
The unit should be completely inspected at the
time of receipt from the carrier before the bill of
lading is signed. Each unit has Tip-N-Tell
indicator on the outside of the crate. This
indicates if the unit has been turned on its side.
If the Tip-N-Tell indicator is tripped, do not sign
for the shipment. Note the information on the
carrier’s paperwork and request a freight claim
and inspection by a claims adjuster before
proceeding. Any other visual damage to the
packaging materials should also be made clear
to the delivering carrier.

2.2 UNPACKING

Carefully unpack the unit by removing the
packaging material. Take care not to damage
the unit jacket when cutting away packaging
materials. A close inspection of the unit should
be made to determine if there has been any
damage during shipment that was not indicated
by the Tip-N-Tell.

The freight carrier should be notified immediately
if any damage is detected. The following
accessories come standard with each unit and
are packed separately within the unit’s packing
container

Spare Spark Ignitor

Spare Flame Detector

Manual 1-1/4" Gas Shutoff Valve

Drain Valve Assembly

ASME

Pressure/Temperature

Relief Valve

Ignitor Removal Tool (One per Site)

Regulator Adjustment Tool (One

per

Site)

2 Lifting Lugs

Stainless Steel Condensate Cup

Flue Clamps (2 Pieces)

Optional accessories are also separately packed
within the unit’s packing container. Standard and
optional accessories shipped with the unit
should be identified and put in a safe place until
installation/use.

Figure 2.1

Heater Clearances

Advertising