American Access Systems Advantage DKE - Metal - 26-100L User Manual

Page 7

Advertising
background image

Page 7 American Access Systems / Security Brands, Inc.

“4”

Sub-Mode 4 (Set Relay Output Time from 1/2 to 9 seconds)
To set the relay output time in seconds enter the P5ESE1T MASTE5 CODE, followed by 4, and then the relay output

time in seconds. 1OTE “0” /2 seconds.

(PRESENT MASTER CODE) + 4 + (RELAY OUTPUT TIME)
Should you make an entry error, simply press the key and reenter the correct data. You may enter any single digit

value corresponding from /2 to 9 seconds of total length output time. Please note that when you enter “0”, the

output time is set to /2 seconds.

“5”

Sub-Mode 5 (Set Latch Code)
E;PLA1ATIO1 The Latch Code toggles the state of the main relay (A) of the circuit board. The latch code is useful in

applications where the gate is desired to hold open. If the operator’s close circuit is controlled by loops, timers, etc.,

they will be overridden by the latched state of the relay and the gate will hold open. An “OPE1O9E55IDE” circuit

must exist in the operator in order to utilize this function. If your gate cycles when this code is entered, your operator

is not set up to utilize this function. Your local dealer or distributor should be able to assist you if you have any speciÀc

questions.

To program or change your latch code enter the following;

(MASTER CODE) + 5 + (LATCH CODE)
Should you make a code entry error, simply press the * key and enter the correct code. You may select any 4 digit

latch code you wish. If you receive an E55O5, you must select another code as it is already in use. The unit will

respond with a *OOD BEEP with the acceptance of the new Latch Code and you will be exited from the program

mode. If the unit is in Latch Open and you do not know the 4 digit Latch Code, follow the instructions for resetting

the Master Code on page 5. This will release the Latch Code and return to normal operation. 1OTE On gates with a

timer to close the “TIMED DU5ATIO1” starts when the latch code is released.

“0”

Sub-mode 0 (Clear memory) !!!! WARNING ALL ACCESS CODES WILL BE DELETED !!!!
To delete all access codes from memory enter the MASTE5 CODE, followed by 0, and the reenter the MASTE5 CODE.

(MASTER CODE) + 0 + (MASTER CODE)
Should you make an entry error, simply press the * key and reenter the correct data. If the second entry of the

master code is correct there will be a short pause before a *OODBEEP is heard and then the unit will automatically

be exited from the program mode. If the second entry of the master code is incorrect, the unit will still respond with a

*OODBEEP indicating that it is exiting the program mode however, there will be no pause on the *OODBEEP and the

memory will not be erased.

NOTE: It should not generally be necessary to erase all access codes from memory unless codes are forgotten and

are occupying necessary memory space. A good log and maintenance of access codes should prevent this from

ever needing to be done.