SUBMODE 106 (SET SYSTEM FACILITY CODE(S))
DESCRIPTION: The facility code must be set, for any of your cards to work with the system. The facility code can

usually be found on the back of your cards. The PROX 2000 can handle a maximum of 3 facility codes.

Note: The facility codes for the unit must reside between 0 and 255.
To program in your facility code(s) simply press in your 4 digit “MASTER CODE” followed by submode “106” followed

by your 3 digit facility code, you can continue to enter facility codes until you have entered the maximum of 3. If you

have less than 3, then when you are done press # to exit.
(MASTER CODE) + 106 + ( 3 DIGIT FACILITY CODE) + ( 3 DIGIT FACILITY CODE)..... # TO EXIT
EXAMPLE: PUT IN FACILITY CODES 115 AND 4.

1251 + 106 + 115 + 004 + # TO EXIT

NOTE: ANOTHER WAY TO PROGRAM IN YOUR FACILITY CODE IS TO PUT IN YOUR MASTER CODE FOLLOWED BY 106 THEN

TOUCH ONE OF YOUR ACCESS CARDS TO THE READER THREE TIMES(BEFORE THE UNIT TIMES OUT, THIS IS PROBOBLY A

TWO PERSON JOB)

“108”

SUBMODE 108 (PROGRAM MASTER CODE)
DESCRIPTION: The master code is used to gain access to the program mode. The factory default master code is

1251. The master code is only accepted into the system from the master unit. The master code cannot be deleted

from memory, only changed. The master code is not accessible while in the sleep mode (see submode 102).

To program in a new master code enter the 4 digit “MASTER CODE” followed by submode “108” then the “NEW MAS-

TER CODE” you wish to program into the unit.
( MASTER CODE) + 108 + (NEW MASTER CODE)

The unit will respond with a GOODBEEP after acceptance of the new master code and you will automatically be

exited from the program mode. Should you make an entry error, simply press the * key and reenter the correct data.

Should you receive an ERROR after you enter a new master code, you must select a different one as it is already in

use by the system.

NOTE: IF YOU FORGET OR LOSE YOU MASTER CODE SEE THE “MASTER RESET” SECTION ON PAGE 8.

“109”

SUBMODE 109 (CHANGE QUICK ENTRY MASTER CODE)
DESCRIPTION: The quick entry master code is used to enter the program mode and program individual access cards.

The factory default quick entry master code is 1252. The quick entry master code is only accepted into the system

from the master unit. The quick entry master code cannot be deleted from memory, only changed. The quick entry

master code is not accessible while in the sleep mode (see submode 102).

To program in a new quick entry master code enter the 4 digit “MASTER CODE” followed by submode “109” then the

“NEW QUICK ENTRY MASTER CODE” you wish to program into the unit.
( MASTER CODE) + 109 + (NEW QUICK ENTRY MASTER CODE)
The unit will respond with a GOODBEEP after acceptance of the new quick entry master code and you will

automatically be exited from the program mode. Should you make an entry error, simply press the * key.

“110”

SUBMODE 110 (CHANGE QUICK DELETE MASTER CODE)
DESCRIPTION: The quick delete master code is used to enter the program mode and delete individual access cards.

The factory default quick delete master code is 1253. The quick delete master code is only accepted into the system

from the master unit. The quick delete master code cannot be deleted from memory, only changed. The quick

delete master code is not accessible while in the sleep mode (see submode 102).

To program in a new quick delete master code enter the 4 digit “MASTER CODE” followed by submode “110” then the

“NEW QUICK DELETE MASTER CODE” you wish to program into the unit.
( MASTER CODE) + 110 + (NEW QUICK DELETE MASTER CODE)
The unit will respond with a GOODBEEP after acceptance of the new quick delete master code and you will