SK-ACP

Installation & Operating Manual

Windows

®

95/98 Hyper Terminal Setup

In order to connect to a ENTRACOMP

®

28SA-Plus OR SK-ACP access control unit using only Windows,

follow these steps:

1. Click on the start button on the lower left corner of the screen.

2. Select Programs.

3. Select Accessories.

4. Select Hyper Terminal.

5. Double click on Hypertrm.

6. Type Secura Key in the name field.

7. Click OK.
8. The next window will have a selection at the bottom of “Connect Using”. Be sure it is set to “Direct to

Com1”, or whatever com port is available.

9. Click the settings tab at the top of the box.

10. Under Emulation, select VT100.

11. Click OK.

12. Verify the following setting in the next properties box:

(a) Bits per second: 38,400
(b) Data bits: 8
(c) Stop bits: 1
(d) Flow control: None

13. Click OK.
14. The next box should display the greeting and the “Enter Password” prompt. Enter 12345, or the

appropriate password.

15. If this greeting does not appear, press the Enter or Return key once.

16. If the greeting still does not appear, check the wiring between the unit and the PC and test the com port.

17. To exit, click the (X) box on the upper right. Be sure to answer Yes to save the session.

Obtain the technical bulletin “Programming an SK-ACP Using a Terminal Program” from www.securakey.com

E-5