Specifications – Craftsman 82140 User Manual

Page 8

Advertising
background image

8

SPECIFICATIONS

Diode Test

Test current of 1mA maximum, open circuit
voltage 2.8V DC typical

Continuity Check

Audible signal will sound if the resistance is
less than approximately 30

$

Battery Test current

9V (6mA); 1.5V (100mA)

Input Impedance

>1M!

ACV Bandwidth

45Hz to 450Hz

DCA voltage drop

200mV

Display

3 ½ digit, 2000 count LCD, 0.5” digits

Overrange indication

“1” is displayed

Polarity

Automatic (no indication for positive polarity);
Minus (-) sign for negative polarity.

Measurement Rate

2 times per second, nominal

Low Battery Indication

“BAT” is displayed if battery voltage drops
below operating voltage

Battery

one 9 volt (NEDA 1604) battery

Fuses

mA, µA ranges; 0.2A/250V fast blow
A range; 10A/250V fast blow

Operating Temperature

41

o

F to 104

o

F (5

o

C to 40

o

C)

Storage Temperature

-4

o

F to 140

o

F (-20

o

C to 60

o

C)

Operating Humidity

Max 80% up to 87ºF (31ºC) decreasing linearly
to 50% at 104ºF (40ºC)

Storage Humidity

<80%

Operating Altitude

7000ft. (2000) meters maximum.

Weight

9.17 oz. (260g).

Size

4.78” x 2.38” x 1.57” (121.5mm x 60.6mm x
40mm)

Safety

For indoor use and in accordance with
Overvoltage Category II, Pollution Degree 2.
Category II includes local level, appliance,
portable equipment, etc., with transient
overvoltages less than Overvoltage Category III.

Advertising