Chromalox PG424-2 User Manual

Installation, operation, Type u-rp radiant heater, Renewal parts identification

Advertising
background image

(Supersedes PG424-1)

PG424-2

U-RP

161-058090-001

JULY, 2006

4

and

Installation, Operation

RENEWAL PARTS IDENTIFICATION

Type U-RP Radiant Heater

© 2010 Chromalox, Inc.

Specifications – Table A

Dimensions (In.)

B

C

D

Overall

Heated

Overall

Model

Volts

kW

A

Length

Length

Height

U-RP-410V

208 or 275

13.2

11-5/8

57-1/2

48

12

U-RP-410

240 or 480

13.2

11-5/8

57-1/2

48

12

U-RP-420V

208 or 275

26.4

23-5/8

57-1/2

48

24

U-RP-420

240 or 480

26.4

23-5/8

57-1/2

48

24

U-RP-510V

208 or 275

18

11-5/8

75-1/2

66

12

U-RP-510

240 or 480

18

11-5/8

75-1/2

66

12

U-RP-520V

208 or 275

36

23-5/8

75-1/2

66

24

U-RP-520

240 or 480

36

23-5/8

75-1/2

66

24

Please familiarize yourself with these instructions before
attempting to install or connect this radiant heater

4-5/8”

11-3/8”

D

8-1/8”

1-5/8”

4-7/8”

4-1/2”

C

B

A

Before installing
1.
Open carton and remove heater at the place of installation.
2. Check nameplate volt and watt rating against your power supply

voltage and heating requirements of your installation. This name-
plate is located on one end of the heater.

MOUNTING

1. Framing: Fabricate structural support using angle iron or contin-

uous slot metal framing (manufactured by others). Dimension
framing per Table B and Figure 1 for your size panel.

2. Assembly: Position U-RP radiant panel on fabricated structural

support and attach using 1/2” diameter bolts of suitable length
(see Fig. 2).

3. Insulation: Where unusually high work temperatures are encoun-

tered, it may be desirable to insulate backs of heaters with high
temperature fibrous insulation. A suggested method of accom-
plishing this is indicated in Figure 2.

D

I

H

G

F

Terminal Box Cover

2-5/16”

A

1-1/4” Conduit

Opening

1-5/32” x 9/16” Slot (Typ.)

Mtg. Bracket (Typ.)

Figure 1 – Aluminum Extruded Section

Mounting – Table A

Dimensions (In.)

No. of Mounting

Model

Brackets

F

G

H

I

U-RP-410V

2

44-3/4

8-5/8

U-RP-410

U-RP-420V

2

44-3/4

20-5/8

U-RP-420

U-RP-510V

3

62-3/4

32-1/4

30-1/2

8-5/8

U-RP-510

U-RP-520V

3

62-3/4

32-1/4

30-1/2

20-5/8

U-RP-520

Figure 2 – Typical installation

Insulation

Structural

Support

Bolt

Radiant Panel