Installation – Curtis Computer 1608 User Manual

Page 6

Advertising
background image

3

Flash Pattern

Indication

Yellow on

AC power present

Green on

Charge complete

Green blinking

Charging

Yellow & Green on simultaneously

Charger in standby mode

Yellow & Green blink simultaneously

No battery/reverse polarity

Yellow blinks 1X

Not reaching constant voltage setpoint

Yellow blinks 2X

Not reaching 24V within 2 hours

Yellow blinks 3X

Charge current/voltage does not normalize

Yellow blinks 4X

Battery voltage too high (over 32V)

Yellow blinks 5X

Charger over temperature

3. Restart: If the battery self-discharges below 12.9V for 12V batteries or below

25.7V for 24V batteries while the charger is in standby, the charger cycles into a
constant current of 1.0A (4A models)/2.0A (8A models) until the constant
voltage setpoint is reached. The unit will regulate and terminate as in Constant
Voltage Mode.

2.8 Indication Lights

The charger features built in diagnostics. Refer to the table below to interpret the
flashing of the yellow and green indicator lights. Flashing of the yellow indicator
means that the charging cycle has ended early and the battery may not be fully
charged. Refer to the Troubleshooting section to correct these faults.

INSTALLATION

• Charger should be securely mounted on a flat surface.
• The power cord to the IEC 320/C14 connector should be of the appropriate

gauge to carry a 10A current @ 120VAC, or a 5A current @ 230VAC for
the cable’s length, to meet the requirements of applicable electrical codes.

• A minimum of 30mm clearance should be provided at each end of the

charger for vented models.

• The charger should not be installed in locations which restrict air flow.

Curtis 1604/08 Manual