Cooper Lighting PN3MR User Manual

Cooper Lighting Accessories for water

Advertising
background image

C A T A L O G # :

T Y P E :

Specification grade, wet listed 71 watt

MR16 lamp adjustable fixture.

Adjustment mechanism features hot

aiming capability, aiming marks and too-

less locking. Optics provide glare-free

50° cutoff to lamp and lamp image. For

use with all halogen MR16 lamp vari-

eties. Units small size is ideal for tight

construction areas. Insulation must be

kept 3" away from sides and top of fix-

ture. Optical element can be changed

after installation to provide a variety of

distributions. e.g. into a Downlight

. . .

Re f l e c t o r

.040 thick aluminum spun parabolic interior

reflector in Clear, Gold, Haze, Warm Haze, Black

Alzak® finish

.

Special cone colors listed below.

. . .

G l a s s

.125 thick tempered clear glass protects lamp

from direct spray of water and is retained during

relamping.

. . .

F l a n g e

Self flange reflector or die-cast flange with either

matte white or clear coat finish

Die-cast flanges

are easily removed for field painting. Elements are

keyed for proper insertion.

. . .

A d j u s t a b i l i t y

Removable lamp adjustment mechanism provides

up to 45° tilt and 361° rotation and locks into any

aiming position. Unit is relamped without unlocking

adjustments. Translating centerbeam optics maxi-

mize light output.

. . .

L e n s

Soft focus lens standard for smooth beam

patterns. Up to two filter media can be used

which are retained during relamping.

. . .

A t t a c h m e n t

Positive torsion springs pull flange tight to ceiling.

Mechanical light trap eliminates spill light at edge

of flange or reflector.

. . .

So c k e t

GX5.3 base for Bi-pin MR16 lamps. Back light

shield keeps interior of fixture dark.

. . .

T r a n s f o r m e r

Truvolt

toroidal transformer with dual-output taps

for proper 12.0V operation and quiet operation

when dimmed. Dimmer tap compensates for inher-

ent voltage loss from dimmers, resulting in 30%

more lumens than traditional laminated transform-

ers. Toroidal design, with 90% or greater efficien-

cy, features a rolled one-piece continuous core of

M3 grade grain oriented silicon steel complete with

an integral thermal to protect against overheating.

For dimming, use dimmers rated for electromagnet-

ic transformers. Transformer is warranted for 5

years and is serviceable from below ceiling.

Note: If a dimming system is operated for con-

struction lighting in its "shunt" mode, i.e. bypass-

ing the dimmer modules, for an extended period of

time, fixtures with the dual-tap toroidal transformer

should be operated on the "Switched Fixture" out-

put until the dimmers are in use. Operating fixtures

on the "Dimmed Fixture" output with a full 120v

input for an extended period will overdrive the

lamp and cause shortened lamp life.

. . .

F r a m e / H o u s i n g

Hot dipped galvanized 20 gauge steel frame

with built in 1/2 inch plaster lip. Gunsights allow

for consistent alignment.

. . .

J u n c t i o n B o x

18 cubic inches, listed for 4#12 AWG or 6#14

AWG 90° C additional feed through conductors,

has three 1/2" pryouts.

. . .

B a r H a n g e r s

No Flex

®

bar hangers with positive locking, for

use with wood, engineered wood and steel frame

joists spaced up to 24" O.C. ship with platform.

For use in T-bar ceilings order accessory push on

clips. Nailess barb and locator lip provide consis-

tent installation height.

. . .

C o d e s

Thermally protected, IP labeled. Unit is airtight and

exchanges less than 2.0 CFM with the plenum at a

pressure of 75 pascals. Insulation must be kept

three inches away from fixture sides and none on

top as to entrap heat.

. . .

L a b e l s

                    





      

3 " A D J U S T A B L E

S H O W E R





          

3 1/2"

[89mm]

4 3/8"

[112mm]

5 1/8"

[130mm]

5"

[127mm]

8 5/8"

[220mm]

4 3/8"

[112mm]

11 7/8"

[302mm]

E N E R G Y D A T A

120V Input

Lamp

Input Operating

Watts

Watts

Current

20

23

.19

35

41

.34

37

42

.35

42

47

.39

50

57

.48

65

70

.58

71

77

.64

75

81

.68

Note: O.D. on SF

is 4 7/8"

Ceiling Cutout:

4 3/8" [112mm]

ADI042551

                  
S A M P L E N U M B E R : P N 3 M R - E 3 A A S R C

Complete unit consists of a platform and element

 



PN3MR = 3" Non-

IC Low Voltage

Housing
PN3MR REMOTE =

3" Non-IC Housing

for Remote

Transformer

P l a t f o r m

A c c e s s o r i e s

MBCLP = 40

Push On T Bar

Clips (for 10

Units)
PLE3 = Plaster

Lip Extension

for Max 2"

Thick Ceiling
L-SPD =

Spread Lens
L-LNR = Linear

E3AASR

= 3"

MR16

0 - 45°

Adjustable

Accent

Lensed

Reflector

O p t i c a l

E l e m e n t

Blank= White

die-cast
SF= Self

Flange
SFWF= Self

Flange Painted

White
RAW= Natural

Die Cast

F l a n g e

F i n i s h

Standard
C=Clear
H=Haze
G=Gold
WMH=Warm

Haze
W=Gloss White
B= Black
MW= Matte

White
Custom
K=Cognac
KH=Cognac

Haze
CC=Chocolate
Custom
CCH=Chocolate

Haze

BU=Blush
Custom Cont.
BUH=Blush

Haze
GP=Graphite
GPH=Graphite

Haze
PN=Pine
PNH=Pine Haze
SK=Sky
SKH=Sky Haze

Spread Lens
L-UV = UV

Reduction Lens
L-LPINK =

Light Pink
L-LSTRAW =

Light Straw

Lens
L-27K =

2700K dichroic

filter

L-DAY =

Daylight Lens
L-SPINK =

Surprise Pink

Lens
L-PLAV = Pale

Lavender Lens
L-HEX= Hex

Cell Louver

For additional options please consult factory.

Matte white is recommended for self flanged reflectors

Advertising
This manual is related to the following products: