20

- User and Installation Manual

AvMap

Ultra EFIS

User and Installation Manual -

21

AvMap

Ultra EFIS

error in the attitude estimation during these high dynamic conditions, but this error is

automatically reduced and eliminated even on dynamic conditions (provided limits are

not continuously exceeded). If this failure occurs in non-high dynamic conditions, unit

requires service.

Altimeter failure

When the altimeter in the unit is either out of range or not operating correctly the

altimeter tape becomes RED.

What to do?

If the altitude is within the limits of the unit (as quoted in the specifications), check for a

static port blockage. If the static port is not obstructed, the unit requires service.

Unit failure

When the PFD and HSI display modes show a RED cross the system is not operative.

This failure indicates that the sensor system on the unit is no longer speaking to the

symbol generator CPU.

What to do?

This problem can occur because the unit is configured wrong, because the software

on the device inside it has been erased, or because of an internal failure. The first

two causes can be solved by updating the software with the latest available software

version. If a software update doesn’t resolve the failure the Ultra requires service at

AvMap facility.