16

7.2. Electrical installation

DANGER!

Risk of injury due to electrical shock!
• Before reaching into the system, switch off the power

supply and secure to prevent reactivation!

• Observe applicable accident prevention and safety

regulations for electrical equipment!

WARNING!

Danger of electrical shock if the protective conductor
contact between the coil and housing is missing!
• Always connect protective conductor.
• Check electrical continuity between coil and housing.
Risk of short-circuit or escape of media through
leaking screw joints.
• Ensure seals are seated correctly!
• Carefully screw together coil and device socket or valve

and pipelines!

Note the voltage and current type as specified on
the label.

english

17

max. 1 Nm

Seal

Authorised cable plug
Type 2508

Fig. 1:

Electrical installation

english

18

8. MAINTENANCE,

TROUBLESHOOTING

8.1. Safety instructions

DANGER!

Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the pres-

sure and vent the lines.

Risk of injury due to electrical shock!
• Before reaching into the system, switch off the power

supply and secure to prevent reactivation!

• Observe applicable accident prevention and safety

regulations for electrical equipment!

WARNING!

Risk of injury from improper maintenance!
• Maintenance may be carried out by authorized technicians

only and with the appropriate tools!

Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following maintenance, ensure a controlled restart.

english

19

8.2. Malfunctions

Troubles
If malfunctions occur, check whether:
• the device has been installed according to the

instructions,

• the connections are correct,
• the device is not damaged,
• all screws have been tightened,
• the voltage and pressure have been switched on,
• the pipelines are clean.

If the magnet does not pick up, ensure that:
• there is no short-circuit or coil interruption,
• the core / core area is not dirty.

If the valve still does not switch, please contact your Bürkert
Service.