Thank you for purchasing your Leak Controller™, a Water Controller Products device. Your Leak

Controller™ has been designed so it can be easily installed, operated, and maintained. Please read the

following instructions carefully, as we want you to enjoy all of the benefits of your product.

Installation and Operation Guide

For Models LCS25, LCS38, LCP25, LCP38

Features

Benefits

USA manufactured NSF™ approved ball valve with

patent pending one-way spring release

Proven quality and reliability

Audio alarm and LED indicator

See and hear the controller functioning

LeakLogic™ RISC based software

Low battery power management, controller

monitoring, water leak detection sensitivity

Quick-Connect plumbing connections

Fast installation without the need for a plumber for

tubing connections

Sensor with in-series connection capability

Ability to connect as many sensors as needed to a

single controller

Complete testing capability

One button test/silence/reset and direct sensor testing

Multiple uses

Connect to many types of appliances and fixtures

Detachable Battery Holder

Ease in changing batteries in difficult to access

locations

Separate 2 screw mounting plate

Mounts in difficult places in seconds without a

template

Absorbent Sensor Mat

Increased moisture sensitivity

Water Controller Products Inc. (WCP) has carefully tested and inspected the Leak

Controller™ before shipment, and hereby warrants our products to be free of defects in

material and workmanship for a period of 1 year from the date of the original purchase. You

should replace your controller every 5 years since it is in constant contact with your water

supply.

During the warranty period WCP shall, at its sole and absolute discretion, either repair or

replace free of charge any of our products that prove to be defective on inspection by WCP or

its authorized service representative. This warranty does not cover claims for damage due to

abuse, neglect, alteration, or attempted repair by unauthorized personnel, and is limited to

failures arising during normal use that are due to defects in material or workmanship in the

product.

ANY IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE AS SETFORTH IN

THESE INSTRUCTIONS, ARE LIMITED IN DURATION TO THE LENGTH OF THIS

LIMITED WARRANTY. USE OF THIS PRODUCT IS NOT A REPLACEMENT FOR

YOUR INSURANCE POLICY. IN NO EVENT WILL WCP BE LIABLE FOR

INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES RESULTING FROM THE

BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING, AMONG

OTHER THINGS, DAMAGE TO PROPERTY, DAMAGE BASED ON INCONVENIENCE

OR ON LOSS OF THE USE OF THE PRODUCT, AND, TO THE EXTENT PERMITTED

BY LAW, DAMAGES FOR PERSONAL INJURY. THE LIABILITY OF WCP SHALL BE

LIMITED TO REPLACEMENT OF THE DEFECTIVE PRODUCT.

This warranty only applies to products sold and used in North America. For warranty

information in all other countries, please refer to your local distributor.

Use of the Leak Controller™ is restricted to water supply lines in a home, office or
recreational vehicle.

Do not allow small children to play with the controller, their fingers could get stuck or
injured inside of the controller valve. Only insert a pipe, tube or a fitting of the proper

size into the controller valve.

Operate the unit only with “AA” size alkaline type batteries.

Never open the cover to the controller, this will void the warranty and damage the
product.

The sensors can not having anything placed on top of them.

Do not connect the controller to a hot water line; connect only to the cold water supply.

Open the battery door and remove the battery holder. Take this moment to record the

installation date on the inside of the battery door, and on the

space below:

Original Battery Installation Date:
Additional Battery Change Dates:


Gently disconnect the battery holder from the snap connector.

Insert the 4 batteries into the battery holder slots, matching the

positive (+) and negative (-) terminals. Gently reconnect the

snap connector to the battery holder and insert the battery

holder into the battery compartment and close the battery door.

* You should see the blue LED light flash twice, hear the

speaker chirp twice, and then see the LED light flash once

every 5 seconds.

____________
____________

Turn the source water you will be connecting to off. Preferably, the controller will be installed

as far upstream (closest to where the water is access from the main plumbing) as possible from

the device you will be protecting, such as under the kitchen sink or behind an appliance. If you

are going to cut an existing plumbing line, allow for an extra ¾” of tubing on each side of the

controller valve as the valve requires ¾” of pipe or tubing to properly seal.

There are 2 ways to connect the controller to the water line that you want to protect depending

on the type and material of the tubing:

a) Plastic Tubing. Measure the length of tubing needed, and then add

at least one extra foot of tubing for both the incoming and outgoing

lines; this allows you to easily reach the controller. Cut the tubing

with a tube cutter, or very sharp razorblade. It is very important that

the cut is clean and straight through to ensure a good connection into

the quick-connect fittings.

b) Copper Tubing. Measure the length of tubing needed to easily reach the controller, you

may want to use some extra tubing in the event that you have to service the appliance or

controller, if this is the case, loop the extra tubing taking

care that the tubing enters the valve correctly. Use a

simple circular tube cutter (can be purchased from

hardware store) to cut through the tubing in a straight cut.

It is important that the cut is clean and straight through to

ensure a good connection into the quick-connect fittings.

c) Braided tubing. Visit www.leakcontroller.com

Avoid sharp changes in direction when routing the tubing. It is very important to have the

tubing inserted parallel to the valve, do not allow the tubing to exert any upward or downward

force on the valve connection.

Open the valve by turning the front Knob (with the finger-fitting wave grips) ¼ turn clockwise

to the green mark on the cover. Now the controller is open and

loaded. Press the front button and the alarm will sound to activate

the controllers’ test feature. The controller will beep and flash

four times and close the knob back to the red closed position.

Next, the alarm will sound, the LED light will flash twice, and the

controller circuitry will automatically reset itself. Again, open the

valve by turning the front knob ¼ turn clockwise to the green

mark on the cover.

Now the controller is ready to be connected to your water supply

and the controller is in the ready and armed state. The LED light

should be flashing once every 5 seconds, the speaker is off, and

the knob is in the green-armed position.

Package contents:

Main Leak Controller™ controller module with attached 4 1/2-foot sensor cable

4 “AA” size alkaline batteries

Metal Wall Mount Plate with 2 #8 mounting screws

1 sensor mat (paper towels OK for replacement)

* Additional sensors and cable lengths can be ordered

!

"

#$

%

&

"

"

'

"

!

____________

____________ ____________

(

)

& & (

*)

+ (

"

,

-

Quick Reference

The Leak Controller is beeping, how do I shut it off?

••••

The Leak Controller has activated due to one of the following:

1. water touching the sensor (leak or spill)

2. low battery

3. no testing for 2 years and is in maintenance mode

Check for leaks and fix if necessary. Dry sensor(s). Change the

batteries if in doubt. Hold the front button down until the blue

LED light goes solid (stops blinking) and release. Turn the knob

clockwise until locked in position.

Advertising