BG1100M Direct Spark Ignition Control

Application

The BG1100M is a microprocessor based ignition
control. The microprocessor provides reliable software
control of all timings and operates a diagnostic red
Light-Emitting Diode (LED). It is designed for direct
burner supervision and can be used with all gases. It
provides ignition sequence, flame monitoring, and
safety shutoff for direct spark ignition boilers, furnaces
and other heating appliances. For a complete listing of
specifications, refer to the Technical Specifications
section.

Installation

IMPORTANT:

Only qualified personnel should

install or service BASO Gas Products®. These
instructions are a guide for such personnel. Carefully
follow all instructions for the appliance.

IMPORTANT:

Make all gas installations in

accordance with applicable local, national, and
regional regulations.

!

WARNING: Risk of Explosion or Fire.

Do not install the control in an area that is exposed
to water (for example, dripping, spraying, rain). Do
not use the control if it has been exposed to water.
Exposure to water may cause malfunction and can
lead to an explosion or fire and may result in severe
personal injury or death.

IMPORTANT:

This control is approved for use

with only noise suppression (resistive) spark wires. If
the application has copper wire, it must be replaced.

Instructions for installing the burner/igniter-sensor are
typically provided by the appliance manufacturer. It is
important to follow those instructions. If such
information is not included, refer to the Mounting
section.

Mounting

!

CAUTION: Risk of Electric Shock.

Disconnect power supply before making electrical
connections to avoid electric shock.

!

WARNING: Risk of Explosion or Fire.

Shut off the gas supply at the main manual shutoff
valve before installing or servicing the control.
Failure to shut off the gas supply can result in the
release of gas during installation or servicing, which
can lead to an explosion or fire, and may result in
severe personal injury or death.

IMPORTANT:

Do not mount the control where

it can be exposed to direct infrared radiation from the
main burner or to temperatures in excess of the
maximum product temperature rating.