Portable air compressors – Campbell Hausfeld IN628801AV User Manual

Page 6

Advertising
background image

6

www.chpower.com

Notes

Portable Air Compressors

LUbRICATION
This is an oilless type compressor requiring
no lubrication.

THERMAL OVERLOAD PROTECTOR
Turn off the pressure switch or unplug
compressor for 20 minutes and allow it to
cool. Reset the unit. Switch unit to OFF and
turn ON again to resume work.

This compressor is

equipped with a

manual reset thermal overload protector
which will shut off motor if it becomes
overheated.

If thermal overload protector shuts
motor off frequently look for the
following causes.
1. Low voltage.
2. Wrong gauge wire or length of

extension cord.

3. Clogged air filter.
4. Lack of proper ventilation.

The motor must be

allowed to cool down

before start-up is possible. The motor will
automatically restart without warning if
left plugged into electrical outlet, if the
motor is turned on.

STORAGE
1. When not in use, hose and

compressor should be stored in a
cool dry place.

2. Tank should be drained of moisture.
3. Hose should be disconnected and

hung open ends down to allow any
moisture to drain.

Advertising