INSTALLATION

1. Install the compatible Braeburn

®

thermostat as specified in the

Installation Guide.
2. Run two wire cable from the thermostat (terminals S1 and S2) to

the remote indoor sensor location. Maximum distance between the

thermostat and remote indoor sensor is 200ft.
3. Remove front of remote indoor sensor from sub-base by putting a

small flat blade screwdriver in the slot at the bottom of the cover.

Push in on the latch and turn the screwdriver slowly to separate the

cover from the sub-base (see Figure 1).
4. Place the sub-base against the wall in desired location and guide

wires through center hole.
5. Mark placement of mounting holes as appropriate and drill using a

3/16” drill bit.

cont.

Figure 1

INSTALLATION

6. Gently tap supplied plastic anchors into the holes in the wall.
7. Fasten the sub-base of the remote sensor to wall using supplied screws.
8. Connect wires to quick wiring terminal block, one wire in each

connection. The wires can be connected with either polarity.
9. Attach cover of remote indoor sensor to the sub-base by engaging the

hooks at the top and swinging down to engage the snap.

cont.