5300_install_wiring 2.pdf, Wiring diagrams – Braeburn 5300 3H-2C Installer Manual User Manual

Page 9

Advertising
background image

Wiring Diagrams

cont.

6

NOTES:

1. Transformer Common connection not required for battery-only operation of thermostat.

2. Second Stage Control connections not used for single stage heating or cooling systems.

3. For units requiring reversing valve to be energized during heating, connect reversing valve to B

terminal. For units requiring reversing valve to be energized during cooling, connect reversing valve

to O terminal.

4. Required for units with 2 stage heat only. 5. For 2 stage heat units not having a

separate Emergency Heat Terminal, add installer supplied jumper.

6. Remote Sensor Terminals can

be either for Outdoor or Indoor Remote Sensor.

7. If L Terminal is used, 24VAC common (C terminal)

must be connected.

Emergency

Heat Control

(See NOTE 4)

1st Stage

Compressor

Control

2nd Stage

Compressor

Control

(NOTE 2)

2nd Stage

Heat Control

(NOTE 2)

Fan Control

Remote

Sensor

(NOTE 6)

Reversing Valve

(Active in

Cooling - See

NOTE 3)

System

Malfunction

Indicator

(NOTE 7)

(See NOTE 5)

Transformer Common (See NOTE 1)

Neutral

120 VAC

Hot

24 VAC

Reversing Valve

(Active in

Heating - See

NOTE 3)

Outside

Air Control

One and Two Stage Heat Pump Systems

NOTES:

1. Transformer Common connection not required for battery-only operation of thermostat.

2. For units requiring reversing valve to be energized during heating, connect reversing valve

to B terminal. For units requiring reversing valve to be energized during cooling, connect

reversing valve to O terminal.

3. Remote Sensor Terminals can be either for Outdoor or Indoor

Remote Sensor.

4. If L Terminal is used, 24VAC common (C terminal) must be connected.

A

G

Rc

Rh

W2

B

O

Y1

W1/E/W3 C

L

S1

S2

Y2

Remote

Sensor

(NOTE 3)

Factory Installed Jumper

Factory Installed Jumper

Aux Heat

Control

1st Stage

Compressor

Control

2nd Stage

Compressor

Control

Fan Control

Reversing Valve

(Active in

Cooling - See

NOTE 2)

System

Malfunction

Indicator

(NOTE 4)

Transformer Common (See NOTE 1)

Neutral

120 VAC

Hot

24 VAC

Reversing Valve

(Active in

Heating - See

NOTE 2)

Outside

Air Control

Three Stage Heat Pump Systems

A

G

Rc

Rh

W2

B

O

Y1

W1/E/W3 C

L

S1

S2

Y2