Braeburn 5300 2H-2C Installer Manual User Manual

Installer guide, Warning, Premier series

Advertising
background image

© 2006 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 5300-100-003

1

Electrical Rating: 24 Volt AC (18-30 Volt AC)

1 amp maximum load per terminal
3 amp maximum load (all terminals)

Control Range: 45º - 90º F (7º C - 32º C)

Accuracy: +/- 1º F (+/- .5º C)

AC Power: 18-30 Volt AC

DC Power: 3.0 Volt DC (2 “AA” Alkaline batteries included)

Old Terminal from

New Terminal for

Existing Thermostat New Thermostat Terminal Description

R, V-VR or VR-R

R

24 Volt AC

Rc

24 Volt AC (Cooling for Dual

Transformer Systems)

O or R

O

Reversing Valve (Cooling)

E/W1

E/W1

1st Stage Heating for

Conventional Systems or

Emergency Heating for 2 Stage

Heat Pumps

B

B

Reversing Valve (Heating)

Y2

Y2

Stage 2 Compressor

W1, W2 or W-U

W2

Stage 2 Heating

Y, Y1 or M

Y1

Stage 1 Compressor

G or F

G

Fan Control

C, X or B

C

24 Volt AC, Transformer Common

L or X

L

System Monitor

S1

S1

Optional Remote Sensor

S2

S2

Optional Remote Sensor

Premier Series

Universal Auto Changeover

Up to 2 Heat / 2 Cool

Conventional and Heat Pump Thermostat

Installer Guide

Specifications
Installation
Quick Reference
Programming Installer Settings

Before Installing, Programming or Operating,

PLEASE READ ALL INSTRUCTIONS

1
2
3
4

Testing Thermostat
Wiring Diagrams

5
6

5300

SEE USER MANUAL FOR TROUBLESHOOTING

1

Specifications

• Always turn off power to the air conditioning or heating system prior to

installing, removing, cleaning or servicing thermostat.
• This thermostat is a dual power thermostat and either requires 24 Volt
AC Power or two (2) properly installed “AA” Alkaline batteries for normal

operation and control of the heating or cooling system.
• Properly installed batteries will allow the thermostat to retain clock settings
in the event of loss of AC Power due to power outage or rolling

blackouts when used as a hardwired thermostat.
• This thermostat should only be used as described in this manual. Any other
use is not recommended and will void the warranty.

Specifications

1

cont.

Installation

2

Replacing Existing Thermostat

Most existing thermostats have three parts:

• The cover, which may snap or hinge over the existing thermostat.
• The electronics or body, which controls the existing system.
• The sub-base, where the wires attach through the wall to the existing system.
1. Always turn off power to the air conditioning and heating system prior to

removing existing thermostat.
2. Carefully remove the cover and electronics body from the old thermostat

sub-base. Depending on the brand, these parts may pull off or need to be

unscrewed. The old sub-base should remain wired and on the wall until
steps 4 and 5.
3. Label every old wire with the letter of the connection to which the wire is

attached. Example letters are R, M, Y, etc. Depending on the brand of the

old thermostat, your letters may be different.

NOTE: This thermostat is designed for use on low voltage 24 volt AC single stage

or multi-stage systems, including heat pumps with up to two stages of heating

and two stages of cooling. Do not use this thermostat on systems with voltage

higher than 30 Volts AC. This thermostat requires a transformer common wire for

proper installation if used as a hardwired thermostat.

4. After labeling the old wires, loosen each connection and remove them from
old sub-base. Secure the wires to prevent them from slipping into the opening
in the wall.
5. Remove the old sub-base from the wall, again being careful that the wires do
not slip into the opening in the wall.
6. Use the chart below to determine the new thermostat connections. As an

example, if the old thermostat had a G or F connection, it goes to G on the new
thermostat. It may be helpful to use the chart by circling (with a pencil or pen)
the letter of each wire removed from the old thermostat.

Compatibility: Compatible with low voltage single stage or multi-stage heat/cool

systems, including heat pumps with up to two stages of heating and two stages
of cooling. This thermostat can also be used on 250mv to 750mv millivolt heating
only systems.

Terminations: R, Rc, O, W1/E, B, Y2, W2, Y1, G, C, L, S1, S2

WARNING

Important Safety Information