MODEL

1100

Builder Series

Non-Programmable

2 Heat / 1 Cool

Multi-Stage Thermostat

Compatible with low voltage multi-stage

heat / cool systems with up to two stages of

heating and one stage of cooling.

WARNING!

Important Safety Information

• Always turn off power to the air conditioning or heating system prior to installing,

removing, cleaning or servicing thermostat.

• Read this manual thoroughly prior to installing, programming or operating

this thermostat.

• This thermostat is designed for use with a 24 Volt-AC low voltage multi-stage

heat / cool system.

• Do not use this thermostat on systems with voltages higher than 30 Volt-AC.

• This thermostat requires 24 Volt AC power for normal operation and control of

the heating or cooling system.

• In the event of an AC power outage, the first and second stage temperature

differentials and the setpoint will return to their default system values. The user

can change the default settings once power is restored.

• Wiring must conform to all building codes and ordinances as required by local

and national code authorities having jurisdiction.

• Do not short (or jumper) across terminals on the gas valve or at the heating or

cooling system control board to test the thermostat installation. This could

damage the thermostat and void the warranty.

• Do not select COOL mode of operation if the outside temperature is below 50˚ F

(10˚ C). This could possibly damage the controlled cooling system and may

cause personal injury.

• This thermostat should only be used as described in this manual. Any other use

is not recommended and will void the warranty.

SPECIFICATIONS

1

1

• Electrical Rating: 24 Volt AC (18-30 Volt AC)

1 amp maximum load per terminal

3 amp total maximum load (all terminals)

• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)

• Accuracy: +/- 1˚ F (+/- .5˚ C)

• AC Power: 18-30 Volt AC

• Compatibility: Multi-stage heat / cool systems

with up to two stages of heating and one stage

of cooling.

• Terminations: R, O, B, C, Y, W1, G, W2

USER MANUAL

READ ALL INSTRUCTIONS BEFORE PROCEEDING

CONTENTS

SPECIFICATIONS
INSTALLATION
TESTING YOUR NEW THERMOSTAT
PROGRAMMING USER SETTINGS
ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
WIRING DIAGRAM

1

2

3
4
5
6
7

© 2004 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 1100-100-004