500 505 4 warranty, Wiring diagrams, One year limited warranty – Braeburn 505 User Manual

Page 3

Advertising
background image

4

©2013 Braeburn Systems LLC • All Rights Reserved.

500-100-04

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Phone: 866-268-5599

When installed by a professional contractor, this product is backed by a 1 year limited warranty. Limitations apply. For limitations,

terms and conditions, you may obtain a full copy of this warranty:

· Visit us online: www.braeburnonline.com/warranty

· Phone us: 866.268.5599

· Write us: Braeburn Systems LLC

2215 Cornell Avenue

Montgomery, IL 60538

WIRING DIAGRAMS

6

Typical 4-Wire Single Transformer Heating and Cooling System

O

G

W

Factory Installed

Jumper

Y

B

Rc

Rh

Cool

Control

Heat

Control

120

Volt AC

Hot
Side T

ransformer

24 Volt AC

Transformer

Fan

Control

Typical 5-Wire Two Transformer Heating and Cooling System

O

G

W

Remove

Factory Installed

Jumper

Y

B

Rc

Rh

Cool 24 VAC

Transformer

120

Volt AC

Heat 24 VAC

Transformer

120

Volt AC

Hot Side Cool

Transformer

Heat

Control

Fan

Control

Cool

Control

Hot Side Hea

t

Transformer

Typical Single Stage Heat Pump Reversing Valve Active in Cooling

O

G

W

Factory Installed

Jumper

Y

B

Rc

Rh

24 Volt AC

Transformer

120

Volt AC

Hot
Side T

ransformer

Fan

Control

See Note 1

NOTES:

1. For Model 505 with Electric Heat, if fan wire is present connect to “W” terminal.

2. For 2-Wire 24 Volt AC or 250mV – 750mV Millivolt Heating Only Systems, remove factory installed jumper.

cont.

WIRING DIAGRAMS

6

NOTES:

1. Installer must place jumper wire between “W” and “Y” terminals.

2. For Typical Single Stage Heat Pump Reversing Valve Active in Heating, reversing valve

must be connected to “B” terminal instead of “O” terminal.

ONE YEAR LIMITED WARRANTY

Compressor

Control

Reversing

Valve

Advertising
This manual is related to the following products:

500