220700 p4.pdf, Year, Care and maintenance – Braeburn 220750 User Manual

Page 4: How the humidifier works, Limited warranty

Advertising
background image

Your Humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried

out at the end of each heating season:

1. Turn off water supply and electrical power to humidifier.

2. Remove cover, water distributor trough, evaporator pad, pad rails and drain pan. Clean excessive mineral

deposits from the distributor trough, drain pan, pad rails and humidifier cabinet. A solution of 1/2 vinegar & 1/2

water will help loosen mineral deposits. Inspect drain hose, clean or replace as necessary.

3. If the evaporator pad has excessive mineral deposits, replace with a new evaporator pad

(229019)

. Install

trough, pad rails and drain pan. Replace cover, reconnect electrical plug.

4. In heavy mineral areas or if the solenoid valve fails to function disconnect the 1/4” water supply line from the

solenoid valve. Carefully pull the strainer screen (229004) from the valve body. Clean the mineral deposits

from all parts. If the orifice is clogged, it may be opened by inserting a small pin. Reinsert the filter into the

valve body.

5. Reconnect the 1/4” water line to the solenoid valve if necessary. Turn on the water supply and check all points

for leakage. The operation of the unit may be checked by starting the furnace. The humidifier operates only

when the furnace blower is running or the burner circuit is energized. The humidifier is now ready for operation.

6. During the summer, turn off water supply and electrical power to humidifier.

CARE AND MAINTENANCE

AT

OUTSIDE

TEMPERATURE

RECOMMENDED

SETTING

The operating principle of the humidifier is based on an efficient and economical means of evaporating water to the air. The heat necessary for

evaporating water is produced by the furnace.
The water supply to the humidifier is controlled by the electric solenoid valve. The solenoid valve and humidifier fan are controlled by a humidistat

connected through an isolation relay. The humidistat is designed for wall mounting in the living area or surface mounting on the return air duct.
ELECTRICAL RATING: 24 VAC/ 60 Hz.
DO NOT SET RELATIVE HUMIDITY TOO HIGH DURING COLD WEATHER. EXCESSIVE HUMIDITY MAY CAUSE CONDENSATION ON WINDOWS

OR IN WALLS. REFER TO RECOMMENDED SETTINGS AS DESCRIBED IN THE HUMIDISTAT OWNERS MANUAL.
Water flows through a strainer, is metered through an orifice to provide the proper amount of water, and is supplied to the evaporator pad by the distributor

trough. Air from the warm air plenum is pulled through the wetted evaporator pad by the humidifier fan and returned to the warm air plenum to be

circulated through the living area. Moisture is evaporated to the air passing through the evaporator pad.
Minerals are not blown into the air stream as occurs in atomizing humidifiers; they are left on the evaporator pad where a high percentage is carried off

with the waste water.
When the humidifier is installed and operating, no adjustments are necessary other than setting the control knob on the humidistat to the desired level of

humidification.
To turn the humidifier off, close water supply valve, switch electrical power off and turn humidistat off.

HOW THE HUMIDIFIER WORKS

©2009 Braeburn Systems LLC • All Rights Reserved • 2207-100-001

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)

40°F 4°C

45%

30°F -1°C

40%

20°F -7°C

35%

10°F -12°C

0°F -18°C

30%

25%

-10°F - 23°C

-20°F -29°C

20%

15%

LIMITED WARRANTY

Braeburn Systems LLC warrants each new Braeburn humidifier against any defects that are due to faulty material or workmanship for a period of five

years after the original date of purchase by a professional service technician. This warranty and our liability does not include damage to merchandise or

the humidifier resulting from accident, alteration, neglect, misuse, improper installation or any other failure to follow Braeburn installation and operating

instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn humidifier under warranty provided it is returned postage prepaid to our

warranty facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This

limited warranty does not include the cost of removal or re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any

questions regarding our limited warranty may be obtained by writing our corporate offices.

WARRANTY FACILITY: Braeburn Systems LLC

Attn: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538

5

YEAR

WARRANTY

LIMITED

Advertising
This manual is related to the following products: