5490_2_3.pdf, Installation – Braeburn 5490 User Manual

Page 2

Advertising
background image

INSTALLATION

cont.

1. Install the Braeburn

®

thermostat as specified in the Installation Guide.

2. Run two wire (22 gauge minimum) cable from the thermostat (terminals

S1 and S2) to the remote outdoor sensor location. Maximum distance

between the thermostat and remote outdoor sensor is 200ft.

3. Use non-hardening caulk to plug any wiring holes.
4. Install the Remote Sensor Hanging Bracket using the screws and

anchors supplied.

5. Place the remote outdoor sensor into the bracket (see Figure 1).
6. Connect wires to the sensor leads using the wire nuts supplied.

The wires can be connected with either polarity.

7. After completing the installation, please refer to the thermostat

Installation Guide to verify proper remote sensor operation.

Mounting

Surface

Figure 1

INSTALLATION

cont.

NOTE:

To use the remote outdoor sensor, you must select the

outdoor remote sensor function for the S1 and S2 thermostat terminals

during Installer setup (see the thermostat Installation Guide).

Advertising