229100 p2, Limited warranty – Braeburn 229100 User Manual

Page 2

Advertising
background image

©2014 Braeburn Systems LLC • All Rights Reserved • 229100-100-002 (MHX3-06B REV B)

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)

ACC

EAC

(HOT)

C

115v.

60CY.

ON-OFF SWITCH

COMMON LEAD

FURNACE

C

HI

LO

229050

CURRENT

SENSING

RELAY

MULTI

SPEED

BLOWER

MOTOR

24V. SOLENOID VALVE

HUMIDISTAT

24 V. TRANSFORMER

ACC

EAC

(HOT)

C

115v.

60CY.

ON-OFF SWITCH

24V. SOLENOID VALVE

24V. SOLENOID VALVE

24 V. TRANSFORMER

L1

C

NO

(HOT)

L2

115v.

60CY.

ON-OFF SWITCH

AIR PRESSURE

SWITCH

24 V. TRANSFORMER

HUM

FURNACE

CONTROL BOARD

C

24v.

60CY.

24V. SOLENOID VALVE

HUMIDISTAT

HUMIDISTAT

HUMIDISTAT

FURNACE

BOARD

Braeburn Systems LLC warrants each new Braeburn humidistat against any defects that are due to faulty material or workmanship for a period of one year after

the original date of purchase by a professional service technician. This warranty and our liability does not include damage to merchandise or the humidistat

resulting from accident, alteration, neglect, misuse, improper installation or any other failure to follow Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn humidistat under warranty provided it is returned postage prepaid to our warranty

facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This limited warranty

does not include the cost of removal or re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any questions

regarding our limited warranty may be obtained by writing our corporate offices.

LIMITED WARRANTY

ACC

EAC

HOT

MANUAL HUMIDISTAT

120 VAC WITH CONTROL FROM FURNACE BOARD

FURNACE
OR FAN
CONTROL

120 VAC

FURNACE

CONTROL

FIELD SUPPLIED
RECEPT & SWITCH

C

HUMIDIFIER

RED

POWER TO HUMIDISTAT

YELLOW

CONTROL

NOTE:

Red wires are for humidistat power if required.

DO NOT CONNECT RED WIRES TO ANOTHER POWER

SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.
NOTE:

Yellow wires are for Humidistat Control. DO NOT APPLY VOLTAGE

TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.

CAP OFF -

DO NOT CONNECT

TOGETHER

HUMIDISTAT

HOT

MANUAL HUMIDISTAT

120 VAC WITH CURRENT SENSING RELAY

FIELD SUPPLIED
RECEPT & SWITCH

C

HUMIDIFIER

RED

POWER TO HUMIDISTAT

YELLOW

NOTE:

Red wires are for humidistat power if required.

DO NOT CONNECT RED WIRES TO ANOTHER POWER

SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.
NOTE:

Yellow wires are for Humidistat Control. DO NOT APPLY

VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.

CURRENT

SENSING

RELAY

SINGLE OR

MULTI-SPEED FAN

C

HI

LO

CAP OFF -

DO NOT CONNECT

TOGETHER

HUMIDISTAT

WARRANTY

FACILITY:

Braeburn Systems LLC

Attn: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538

PRECAUTIONS

The installer should be a qualified Technician. Disconnect electrical power before beginning installation. Use contacts C and NO

for humidifier operation. Use contacts C and NC for a dehumidifier. Conduct a thorough checkout before leaving the installation.

WIRING DIAGRAMS FOR BRAEBURN

®

220500 and 220600 HUMIDIFIERS

WIRING DIAGRAMS FOR BRAEBURN

®

220700 HUMIDIFIER

On furnaces with output terminals ACC, or EAC check output voltage to determine

that terminals are 115V. Connect on-off switch in series with the hot wire.

On furnaces where it is desirable to use a current sensing relay, the

humidifier may be wired from a continuous 115 volt power source. Install the

on/off switch in series with the hot or black wire. Install the Braeburn

®

229050

Current Sensing Relay in series with the humidistat circuit. The Current

Sensing Relay will detect furnace operation and supply power to the

humidifier accordingly.

C

NO

NC

C

NO

NC

C

NO

NC

C

NO

NC

C

NO

NC

C

NO

NC

USE BOTH WITH
WALL MOUNTING

USE WITH DUCT
MOUNTING ONLY

USE OUTSIDE
PORTION ONLY
WITH DUCT
MOUNTING

GASKET PLACEMENT

FIG. 3*

DUCT MOUNT

VERSION

FIG. 2

DUCT MOUNT BASE

DUCT MOUNT BASE
GASKET

SCREWDRIVER PRY SLOT

WALL MOUNT BASE (229110)
(can mount on duct with
gaskets shown)

*Requires wall mount kit (Model 229110)

Advertising