GENERAL COMMENTS:

CAMCORP supplies air pump packages comprised of positive displacement blowers
manufactured by various companies. A Service Manual for your specific blower is
included as an inset in this manual. For specific maintenance and lubrication
information, please refer to this insert.

-READ & UNDERSTAND SAFETY DECALS-

Installation and Operation Cautions:

Be sure that the motor is wired for correct rotation; some models of blower are
unidirectional and damage could occur if rotation is reversed. Refer to certified drawing
or consult CAMCORP representative for rotation.

Blowers are shipped without lubrication oil, do not operate before lubrication.

All system piping must be clean internally before connecting to blower.

Check lubrication level only when blower is stopped.

Keep inlet and inline filters clean.

Keep belts properly tensioned and aligned.

Use of a check valve on pressure and combination packages will prevent reversing of
blower on shutdown.

Keep pressure and/or vacuum relief valves in good condition so that maximum pressure
or vacuum is not exceeded.

Never attempt to regulate airflow by restricting intake or exhaust of a positive
displacement blower.