Maintenance and storage, Danger, Storage – Champion Power Equipment 76555 User Manual

Page 22: Generator battery

Advertising
background image

19

REV 76555-20140718

ENGLISH

76555

MAINTENANCE AND STORAGE

Storage

The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
longer term storage, please follow these guidelines.

Generator Storage

1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the

generator.

3. Run the generator for a few minutes so the treated

fuel cycles through the fuel system and carburetor.

4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has

stopped the engine. This usually takes a few
minutes.

6. The generator needs to cool acompletely before

cleaning and storage.

7. Clean the generator according to the maintenance

section.

8. Change the oil.
9. Remove the spark plug and pour about 1⁄2 ounce

(14.8 mL) of oil into the cylinder. Crank the engine
slowly to distribute the oil and lubricate the cylinder.

10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct

sunlight.

Generator Battery

This product is equipped with an automatic battery
charging circuit. The battery will receive charging
voltage when the engine is running. The battery will
maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle
charger or battery maintainer to keep the battery
properly charged. If the battery is not able to start the
engine, it can be started by manually pulling the engine
recoil cord. If the battery voltage is extremely low,
the charging circuit may not be able to re-charge the
battery. In this case, the battery must be connected to a
standard automotive style battery charger for re-charging
before it can be used.

Disconnect the Battery

1. Remove the protective cover from the black/negative

battery lead.

2. Disconnect the black/negative lead from the black/

negative terminal on the battery and store the cap
screw and nut.

3. Repeat steps 1-2 for the red/positive battery lead.
4. Store the battery in a cool, dry place.

A Float Charger will maintain the battery condition
over long storage periods.

NOTE

Charge the Battery

For a generator equipped with batteries for electric
starting, proper battery maintenance and storage should
be followed. An automatic battery charger (not included)
with automatic trickle charging capability should be used
to charge the battery. Maximum charging rate should not
exceed 1.5 amps. Follow the instructions included with
the battery charger. The battery should be fully charged
at least once per month.

Generator exhaust contains odorless and colorless
carbon monoxide gas.

To avoid accidental or unintended ignition of your
remote start generator during periods of storage,
the following precautions should be followed:

– When

storing the generator for short periods of

time make sure that the Ignition Switch, the Fuel
Valve and the Battery Switch are set in the

OFF

position.

– When

storing the generator for extended periods

of time make sure that the Ignition Switch, the
Fuel Valve and the Battery Switch are set in the
the the

OFF position and the battery leads have

been

disconnected from the battery.

DANGER

Advertising