Etting the, Tarting, Ddress – Chauvet LEDRAIN 64C User Manual

Page 15: Eneral, Roubleshooting, Ontact, Setting the starting address, General troubleshooting, Contact us

Advertising
background image


5. Appendix

15

4/19/2010 12:44 PM

Setting the Starting Address

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address

from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel

indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start

on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start

addresses so that the channels used do not overlap, and note the start address selected for future reference.

If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping to the
“Appendix” section and reading the heading “DMX Primer”. It contains very useful information that will help you

understand its use.

General Troubleshooting

S

YMPTOM

P

OSSIBLE

C

AUSE

(

S

)

P

OSSIBLE

A

CTION

(

S

)

Breaker/Fuse

keeps blowing

Excessive circuit load

Check total load placed on the electrical circuit.

Short circuit along the power

wires

Check for a short in the electrical wiring (internal and/or

external)

Device does not

power up

No power

Check for power on power outlet

Loose power cord

Check power cord

Fixture is not

responding to

DMX

Wrong DMX addressing

Check Control Panel and unit addressing

Damaged DMX cables

Check DMX cables

Wrong polarity settings on the

controller

Check polarity switch settings on the controller

Loose DMX cables

Check cable connections

Faulty DMX interface

Replace DMX input

Faulty Main PCB

Replace Main PCB

Loss of signal

Non DMX cables

Use only DMX compatible cables

Bouncing signals

Install terminator as suggested

Long cable / Low level signal

Install amplifier right after fixture with strong signal

Too many fixtures

Install an optically coupled DMX splitter after unit #32

Interference from AC wires

Keep DMX cables separated from power cables or

black lights

If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.

Contact Us

W o r l d W i d e

General Information

CHAUVET®
3000 North 29

th

Court

Hollywood, FL 33020
voice:

954.929.1115

fax:

954.929.5560

toll free: 800.762.1084

Technical Support

CHAUVET®
3000 North 29

th

Court

Hollywood, FL 33020
voice:

954.929.1115 (Press 4)

fax:

954.929.5560 (Attention: Service)

World Wide Web

www.chauvetlighting.com

Advertising