Before you start, Electrical ground' is required, Warning – Whirlpool 3374369 User Manual

Page 2: Tools and materials needed for installation, Parts supplied for installation, Electrical, Requirements, Electrical shock hazard, Recommended grounding method, Electrical requirements

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Before you start...

Proper installatiori is your responsibility.

Moke sure you hove everything necessary

for correct installation. It is the personal

responsibility and obligation of the

customer to contact a qualified installer to

assure that electrical and plumbing

installations meet all national and local

codes and ordinances.

Proper electrical, drain and water supply

lines must be available or must be installed

as specified within shaded area. Plumbing

and wiring should not cross in front of motor

or dishwasher legs. See Electrical, Water

and Drain requirements.

IMPORTANT: Observe all governing

codes and ordinances.

Corner location

2" min. door to

"cabinet or wall. "

Electrical ground'

is required.

See "Electrical

requirements."

DO NOT pinch

power supply

cord or kink

power supply

cable between

dishwasher and

cabinet.

DO NOT install

dishwasher over

carpeted

flooring.

Figure 1

Cut openings -

Grommet

Water line: 1 /2“ hole or larger. required for
Drain line: 1-1/2“ hole

electrical

or larger.

cable or

Power supply cord: 1-1/2" max. power supply

hole.

cord hole cut

Direct wiring: 3/4“ min. hole.

in a metal

cabinet.

The unshaded area must be free

of pipes or wires.

Electrical outlet must be installed

“24“.

6

34“ min.

underside

counter

height.

24“openlng '

width

33-7/8“

min.

height

Figure 2

■ 23-7/8“ width-

/-------

------- N

Back view

L

Check location where dishwasher will

be installed. The location should

provide:

• Easy access to water, electricity and

drainage lines.

• Convenient loading — the best

position is left or right of kitchen sink.

• Opening that is square for proper

dishwasher operation and

appearance.

• Cabinet front that is perpendicular

to floor.

• Protection so that water inlet valve

and drain cannot freeze.

• 1 /4“ minimum clearance between

motor and flooring to prevent motor

from overheating.

WARNING

Electrical Shock Hazard

• It is the personal responsibility and

obligation of the customer to

contact a qualified electrician to

assure that the electrical installation

is adequate and is in conformance

with the Notional Electrical Code,

ANSI/NFPA 70 — latest edition* and

all local codes and ordinances.

Failure to follow these instructions

could result in electrical shock or

other personal injury.

• Electrical wiring and components

must not contact any plumbing

material or drain hose.

• Cabinet opening must completely

enclose sides, top and back of

dishwasher.

Failure to do so may result in personal

injury from exposed wiring.

Personal Injury/Product Damage

Hazard

Avoid opening dishwasher door

before dishwasher is installed.

Dishwasher, before it is installed, may

tip over when door is opened,

resulting in personal injury or product

damage.

Copies of the standards listed may be

obtained from:

•National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

Read and follow the "Electrical

requirements", "Water requirements"

and "Drain requirements" sections

before installing dishwasher.

Tools and

materials needed

for installation:

' 2 adjustable

wrenches

' pliers
' measuring tape
' flat-blade

screwdriver

■ pipe wrench
' keyhole saw

' pipe-joint compound

5/16“ and 1/4“

driver or hex socket

> gloves

90° elbow with 3/8“

N.P.T. external
threads on one end.
The size of the other
end must fit your
water supply line.

Parts supplied for

installation:

• 2 drain hose clamps
• 2, No.-lO

X

1/2“ Phillips-head screws

• drain hose

Remove parts from bag. Check that all

parts were supplied.

Electrical

requirements

^WARNING

Electrical Shock Hazard

• Electrical ground is required on this

appliance.

• If cold water pipe is interrupted by

plastic, non-metallic gaskets or other

insulating materials. Do Not use for

grounding.

• Do Not ground to a gas pipe.

• Do Not modify the power supply

cord plug. If it does not fit the outlet,

have a proper outlet installed by a

qualified electrician.

• Do Not have a fuse in the neutral or

grounding circuit. A fuse in the

neutral or grounding circuit could

result in electrical shock.

• Do Not use an extension cord with

this appliance.

• Check with a qualified electrician if

you are in doubt as to whether the

appliance is properly grounded.

Failure to follow these instructions

couid result in serious injury or death.

If codes permit and a separate

grounding wire is used, it is

recommended that a qualified

electrician determine that the

grounding path is adequate.

A 120-volt, 60-Hz, AC-only, 15-or 20-

ampere, fused eleotrioal supply is

required. Time-delay fuse or oirouit

breaker is reoommended. It is

reoommended that a separate oirouit

serving only this appliance be provided.

Recommended

grounding method

For your personal safety, this appliance

must be grounded. This appliance is

equipped with a power supply cord

having a 3-prong grounding plug. To

minimize possible shock hazard, the cord

must be plugged into a mating,

3-prong, grounding-type wall recept­

acle, grounded in accordance with

National Electrical Code, ANSI/NFPA 70

— latest edition* and all local codes and

ordinances. (See Figure 3.) If a mating

wall receptacle is not available, it is the

personal responsibility and obligation of

the customer to have a properly

grounded, 3-prong, wall receptacle

installed by a qualified electrician.

3-prong,

grounding-type

wall receptacle

3-prong

grounding

plug

power

suppiy

cord

Figure 3

IF POWER CORD CANNOT
BE USED...

When local codes do not permit use of

a power supply cord with an

undercounter dishwasher, the power

supply cord must be removed and

dishwasher wired directly. To direct wire

this product, order kit #4317979.

Electrical connections must be

contained within the terminal box and

meet all local codes and ordinances.

IF THE POWER SUPPLY CORD IS

REMOVED, THE DISHWASHER MUST BE

CONNECTED WITH COPPER WIRE ONLY.

Panel A

Advertising