D j electrical d ) requirements, Electrical ground this appliance, J electrical d ) requirements – Whirlpool ACE094XM0 User Manual

Page 4: Chart-b

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Figure 1

3-PRONG

GROUNDING PLUG

\

GROUND

PRONG 3- PRONG

GROUNDING

TYPE WALL RECEPTACLE

POWER SUPPLY CORD

D

J ELECTRICAL

D ) REQUIREMENTS

For 230 volt and 230/208 volt models with

serial plate amperes up through 12.0

Refer to Chart B for specific wiring and recep­

tacle information to be used.

ALTERNATE GROUNDING METHOD

If changing and properly grounding the wall

receptacle is impossible and where local codes
permit

(consult

your

electrical

inspector),

a

temporary adapter may be plugged into the
existing 2-prong wall receptacle to mate with the
3-prong power supply cord. See Figure 2. THIS,

HOWEVER, IS NOT RECOMMENDED.

If this is done, you must connect the grounded

eyelet on the adapter to the wall receptacle
cover plate screw and from this same screw, you
must connect a separate copper ground wire

(#14 minimum) to a grounded cold water pipe.*

See Figure 2. Do not ground to a gas supply

pipe. Do not connect to electrical supply until
appliance is permanently grounded.

Figure 2

ELECTRICALLY

GROUNDED METAL
COLD WATER PIPE
(REMOVE PAINT, etc.)

GROUND ASSEMBLY

(ATTACH TO GROUNDED

METAL COLD
WATER PIPE)

COVER PLATE

di)

SCREW

ADAPTER

GROUND PRONG

■ POWER SUPPLY CORD

WALL
RECEPTACLE

*Cold water pipe must have metal continuity to

electrical ground and not be interrupted by

plastic, rubber or other electrically insulating

connectors (including water meter or pump)
without adding a jumper wire at these con­

nections.

OBSERVE

ALL

LOCAL

GOVERNING

CODES

AND ORDINANCES.

Do not, under any circumstances, remove the

power supply cord ground plug.

ELECTRICAL

GROUND

THIS APPLIANCE.

IS REQUIRED ON

A three-wire, single-phase 60 hertz AC only
electrical supply is required.

A separate electrical supply is required on a
separately fused circuit. Do not fuse ground-
neutral.

See Chart B for receptacle voltage requirements,

proper fuse size, wire and wiring connections

which must conform with rating of the appliance.

Do not use an extension cord.

Chart-B

PLUG AND

RECEPTACLE

DATA

RECEPTACLE

RECEPTACLE

VOLTAGE

(M HERTZ

AC IN ALL

INSTANCES)

MODEL WITH

SERIAL PLATE

OF 230 VOLTS

(207 MIN,253

MAX )

MODEL WITH

SERIAL PLATE

OF 230/208

VOLTS

(197.6 MIN

2S3 MAX )

SERIAL PLATE

AMPERES

up

through

12.0

USE TIME-DELAY

MINIMUM

FUSE

OR TIME

RECEPTACLE

TYPE

DELAY CIRCUIT

WIRE SIZE

OF BRANCH

BREAKER

RATING IN

SEE BELOW

CIRCUIT

AMPS

14 GAUGE

SINGLE

OUTLET

USE COPPER

ONLY

15

WIRE ONLY