USING YOUR DEHUMIDIFIER

De-icer control

ÀCAUTION

Product Damage Hazard

Do not operate dehumidifier at tempera­

tures below 55°F (12.8'’C).

Failure to follow the above precaution could

result in the coils icing over and the unit not

operating properly.

Your Whirlpool dehumidifier is equipped with a

feature to help you get the most comfort from
your new appliance by permitting it to operate

down to 55°F (12.8'’C). If your dehumidifier runs
when room temperature and humidity conditions
are low, frost can form on its evaporator coil. This

interferes with proper operation.

The De-icer Control senses frost build-up on

the evaporator coil and automatically shuts off the
compressor. The fan continues to run, drawing air

across the coil and melting the frost. When the

coil is defrosted, the compressor is automatically

restarted, and dehumidifying is resumed.

Adjusting the water level control lever

The Water Level Adjustment can be set in two

positions to turn off the unit automatically when

the pan is full. This prevents the danger of

overflow.

Pan must be in proper position for Water Level

Control Switch to work. The Water Level Control

Switch will automatically turn off the dehumidifier

at the fill level you selected when pan is properly
placed. Loosen the screw to move the Water

Level Control Lever. Retighten screw when

adjusted to desired setting.

NORMAL fill position

Set Water Level Control Lever to the indentation
on the left side. The water pan and water will

weigh approximately 16 lbs. (7.2 kg) and water
pan will be Vi full.

MAXIMUM fill position

Set Water Level Control Lever to the raised area

on the right side. The water pan and water will
weigh approximately 24 lbs. (10.8 kg) and water
pan will be % full.