■ A" = 30" MIN. CLEARANCE BETWEEN

THE TOP OF THE COOKING PLATFORM
AND THE BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET.

"A" = 24" MIN. WHEN BOTTOM OF WOOD
OR METAL CABINET IS PROTECTED BY

NOT

LESS

THAN

FLAME

RETARDANT

MILLBOARD COVERED WITH NOT LESS
THAN NO. 28 MSG. SHEET STEEL, 0.015"
STAINLESS STEEL, 0.024" ALUMINUM OR
0.020" COPPER.

CAUTION: To eliminate the hazard of reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided. If cabinet
storage is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5 inches beyond the bottom of the cabinets.

28%" WRAP TO WRAP

INCLUDING SCREW HEADS

FOR COUNTERTOP AND CABI JET FRONT
CUT-OUT DIMENSIONS —SEi: F RONT AND
TOP VIEWS OF CABINET SHO' VN BELOW

LOCATE

electrical

SUPPLY JUNCTION IlOX

ON FLOOR OR 0 J

REAR WALL NEA 1

FLOOR LINE.

%" MIN. REQUIRED BETWEEN

CUTOUT AND HINGE OR DOOR

WALL LINE

^___________

C JJNTERTOP

23"

CABINET

FRONT

i

T

FRONT

COUNTEFtTOP OPENING

i---- 29-1/16"—i

CABINET OPENING ♦*

-28-1/2'

48" CABLE

NOTE: ON CABINET TOPS WITH

FORMED FRONT EDGE, SHAVE

RAISED SECTION TO CLEAR

30" WIDE RIM. (SEE SKETCH BELOW)

28-1/2" MINIMUM. IF 28-5/8"

IS AVAILABLE THE CUTOUT

SHOULD BE MADE 28-5/8".

FRONT VIEW

FIGURE 1-ROUGH-IN DIMENSIONS

NOTE:

The Installation must conform to any local codes. The

Set-In Unit may be mounted and secured to the cabinet
similar to regular built-in equipment.

1. CARPENTRY

Prepare the cut-out space, shown in

Figure 1, in the

desired location in the counter top and cabinet. The
support surface

(AVz” high) must be solid and level from

side to side and front to rear. A minimum of %” of
cabinet area on either side of cut-out should be clear
of handles, hinges or any other obstruction.

2. ELECTRICAL REQUIREMENTS

IMPORTANT: OBSERVE ALL GOVERNING CODES

AND ORDINANCES

SAVE THESE INSTRUCTIONS FOR THE LOCAL

ELECTRICAL INSPECTOR'S USE

A. A three-wire or four-wire single phase 120/240 vo t

60Hz AC only electrical supply (or three-wire cr
four-wire 120/208 volt if specified on nameplate) ii >
required on a separate circuit fused on both side;
of the line (time-delay fuse or circuit breaker Ii >
recommended). Do NOT fuse neutral. The fuse siz:;
must not exceed the circuit rating of the appliance;

specified on the nameplate.

NOTE: Wire sizes and connections must conforn

with the fuse size and rating of the appliance i i
accordance with the National Electrical Code an( 1
local codes and ordinances. Do not use an
extension cord.